A. Alzeidan, Tiago F. de Cantalice, K. Vallejo, Paul J. Simmonds, A. Quivy
{"title":"InAs覆盖对(2×4)表面重建生长的亚单层-量子点红外探测器性能的影响","authors":"A. Alzeidan, Tiago F. de Cantalice, K. Vallejo, Paul J. Simmonds, A. Quivy","doi":"10.1109/SBMicro50945.2021.9585765","DOIUrl":null,"url":null,"abstract":"Two infrared photodetectors based on submonolayer quantum dots, having a different InAs coverage of 35% and 50%, were grown, processed and tested. The detector with the larger coverage yielded a specific detectivity of 1.13×1011 cm Hz1/2 W-1 at 12K, which is among the highest values reported in the literature for that kind of device.","PeriodicalId":318195,"journal":{"name":"2021 35th Symposium on Microelectronics Technology and Devices (SBMicro)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of the InAs coverage on the performance of submonolayer-quantum-dot infrared photodetectors grown with a (2×4) surface reconstruction\",\"authors\":\"A. Alzeidan, Tiago F. de Cantalice, K. Vallejo, Paul J. Simmonds, A. Quivy\",\"doi\":\"10.1109/SBMicro50945.2021.9585765\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Two infrared photodetectors based on submonolayer quantum dots, having a different InAs coverage of 35% and 50%, were grown, processed and tested. The detector with the larger coverage yielded a specific detectivity of 1.13×1011 cm Hz1/2 W-1 at 12K, which is among the highest values reported in the literature for that kind of device.\",\"PeriodicalId\":318195,\"journal\":{\"name\":\"2021 35th Symposium on Microelectronics Technology and Devices (SBMicro)\",\"volume\":\"54 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 35th Symposium on Microelectronics Technology and Devices (SBMicro)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SBMicro50945.2021.9585765\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 35th Symposium on Microelectronics Technology and Devices (SBMicro)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SBMicro50945.2021.9585765","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
制备了两个基于亚单层量子点的红外探测器,其InAs覆盖率分别为35%和50%。具有较大覆盖率的探测器在12K时产生了1.13×1011 cm Hz1/2 W-1的特定探测率,这是同类器件文献中报道的最高值之一。
Influence of the InAs coverage on the performance of submonolayer-quantum-dot infrared photodetectors grown with a (2×4) surface reconstruction
Two infrared photodetectors based on submonolayer quantum dots, having a different InAs coverage of 35% and 50%, were grown, processed and tested. The detector with the larger coverage yielded a specific detectivity of 1.13×1011 cm Hz1/2 W-1 at 12K, which is among the highest values reported in the literature for that kind of device.