太阳能渗透下配电网电能质量事件的研究

Pragati Prajapati, Om Prakash Mahela, Shoyab Ali
{"title":"太阳能渗透下配电网电能质量事件的研究","authors":"Pragati Prajapati, Om Prakash Mahela, Shoyab Ali","doi":"10.1109/SCEECS.2018.8546930","DOIUrl":null,"url":null,"abstract":"This research work aims to present a Stockwell transform based technique for the investigation of the power quality disturbances associated with solar PV system integrated with the utility grid due to the operational events such as switching on and off the capacitor banks, switching on and off the loads, tripping and reclosing the feeders. The power quality disturbances associated with the considered events has been investigated and effectively detected with the help of proposed algorithm using the various S-transform based plots. The detailed simulation study of power quality disturbances has been carried out in MATLAB/Simulink environment using the IEEE-13 bus test system incorporated with the solar PV system.","PeriodicalId":446667,"journal":{"name":"2018 IEEE International Students' Conference on Electrical, Electronics and Computer Science (SCEECS)","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Investigation of Power Quality Events in Distribution Network with Solar Energy Penetration\",\"authors\":\"Pragati Prajapati, Om Prakash Mahela, Shoyab Ali\",\"doi\":\"10.1109/SCEECS.2018.8546930\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This research work aims to present a Stockwell transform based technique for the investigation of the power quality disturbances associated with solar PV system integrated with the utility grid due to the operational events such as switching on and off the capacitor banks, switching on and off the loads, tripping and reclosing the feeders. The power quality disturbances associated with the considered events has been investigated and effectively detected with the help of proposed algorithm using the various S-transform based plots. The detailed simulation study of power quality disturbances has been carried out in MATLAB/Simulink environment using the IEEE-13 bus test system incorporated with the solar PV system.\",\"PeriodicalId\":446667,\"journal\":{\"name\":\"2018 IEEE International Students' Conference on Electrical, Electronics and Computer Science (SCEECS)\",\"volume\":\"55 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE International Students' Conference on Electrical, Electronics and Computer Science (SCEECS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SCEECS.2018.8546930\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE International Students' Conference on Electrical, Electronics and Computer Science (SCEECS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SCEECS.2018.8546930","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本研究工作旨在提出一种基于斯托克韦尔变换的技术,用于研究与公用电网集成的太阳能光伏系统由于操作事件(如打开和关闭电容器组、打开和关闭负载、跳闸和重合闸馈线)相关的电能质量干扰。研究了与所考虑的事件相关的电能质量干扰,并利用基于s变换的各种图有效地检测了所提出的算法。利用太阳能光伏系统集成的IEEE-13总线测试系统,在MATLAB/Simulink环境下对电能质量扰动进行了详细的仿真研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation of Power Quality Events in Distribution Network with Solar Energy Penetration
This research work aims to present a Stockwell transform based technique for the investigation of the power quality disturbances associated with solar PV system integrated with the utility grid due to the operational events such as switching on and off the capacitor banks, switching on and off the loads, tripping and reclosing the feeders. The power quality disturbances associated with the considered events has been investigated and effectively detected with the help of proposed algorithm using the various S-transform based plots. The detailed simulation study of power quality disturbances has been carried out in MATLAB/Simulink environment using the IEEE-13 bus test system incorporated with the solar PV system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信