{"title":"改善配电网电能质量的一些新技术","authors":"Zeng Xiangjun, K. Li, W. L. Chan, Yin Xianggen","doi":"10.1109/DRPT.2004.1338512","DOIUrl":null,"url":null,"abstract":"Power quality is influenced by neutral grounding methods in distribution systems. Optimization for neutral grounding methods is discussed in the paper. Petersen-coil in parallel with high resistance earthed technique has a better performance in safety and power quality than other neutral point grounding techniques. To improve power quality, a novel method for measurement of zero sequence impedance in distribution systems is presented, Petersen-coil inductance is adjusted to compensate the total capacitance, and the resistor which is in parallel with the Petersen-coil is adjusted to control the over-voltage; some other novel techniques for grounding fault feeder protection based on testing the fault resistance or the energy dissipated in the fault point are also presented. The method of Petersen-coil tuning has been developed. Experimental results show that the optimization for neutral grounding methods and the protections proposed can improve the power quality by reducing the over-voltage, the residual current and the grounding fault duration.","PeriodicalId":427228,"journal":{"name":"2004 IEEE International Conference on Electric Utility Deregulation, Restructuring and Power Technologies. Proceedings","volume":"29 6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Some novel techniques for improving power quality in distribution networks\",\"authors\":\"Zeng Xiangjun, K. Li, W. L. Chan, Yin Xianggen\",\"doi\":\"10.1109/DRPT.2004.1338512\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power quality is influenced by neutral grounding methods in distribution systems. Optimization for neutral grounding methods is discussed in the paper. Petersen-coil in parallel with high resistance earthed technique has a better performance in safety and power quality than other neutral point grounding techniques. To improve power quality, a novel method for measurement of zero sequence impedance in distribution systems is presented, Petersen-coil inductance is adjusted to compensate the total capacitance, and the resistor which is in parallel with the Petersen-coil is adjusted to control the over-voltage; some other novel techniques for grounding fault feeder protection based on testing the fault resistance or the energy dissipated in the fault point are also presented. The method of Petersen-coil tuning has been developed. Experimental results show that the optimization for neutral grounding methods and the protections proposed can improve the power quality by reducing the over-voltage, the residual current and the grounding fault duration.\",\"PeriodicalId\":427228,\"journal\":{\"name\":\"2004 IEEE International Conference on Electric Utility Deregulation, Restructuring and Power Technologies. Proceedings\",\"volume\":\"29 6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2004 IEEE International Conference on Electric Utility Deregulation, Restructuring and Power Technologies. Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DRPT.2004.1338512\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2004 IEEE International Conference on Electric Utility Deregulation, Restructuring and Power Technologies. Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DRPT.2004.1338512","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Some novel techniques for improving power quality in distribution networks
Power quality is influenced by neutral grounding methods in distribution systems. Optimization for neutral grounding methods is discussed in the paper. Petersen-coil in parallel with high resistance earthed technique has a better performance in safety and power quality than other neutral point grounding techniques. To improve power quality, a novel method for measurement of zero sequence impedance in distribution systems is presented, Petersen-coil inductance is adjusted to compensate the total capacitance, and the resistor which is in parallel with the Petersen-coil is adjusted to control the over-voltage; some other novel techniques for grounding fault feeder protection based on testing the fault resistance or the energy dissipated in the fault point are also presented. The method of Petersen-coil tuning has been developed. Experimental results show that the optimization for neutral grounding methods and the protections proposed can improve the power quality by reducing the over-voltage, the residual current and the grounding fault duration.