{"title":"老化对聚合物绝缘中压电缆去极化电流的影响","authors":"T. Heizmarm, W.S. ZaengI","doi":"10.1109/CEIDP.1991.763378","DOIUrl":null,"url":null,"abstract":"Depolarization currents in a larger number of virgin and aged polymer-insulated medium-voltage cables have been measured as a function of the magnitude of the applied electric field. In comparison with new cables some service-aged cables revealed unusual dielectric properties. As expected, unaged cables show a lineal relation between the depolarization current and the polarizing field at moderate electric field strengths. In contrast, for many service-aged cables a more than proportional increase of the depolarization current with the applied electric field was observed (indicating some nonlinearity). Visual inspection of the cables showed a very high density of bow-tie trees in the 'non-linear' cables. Furthermore, it was observed that the nonlinearity vanished when the cable was dried and reappeared again after wetting the cable. As a conclusion from these observations, it is believed that the non-linear dielectric behaviour is a consequence of the presence of bow-tie trees in the cables. In our opinion it may be worthwhile considering the measurement of depolarization currents as a diagnostic measurement technique to detect water trees in buried cables.","PeriodicalId":277387,"journal":{"name":"1991 Annual Report. Conference on Electrical Insulation and Dielectric Phenomena,","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Influence of ageing on depolarization currents in polymer-insulated medium-voltage cables\",\"authors\":\"T. Heizmarm, W.S. ZaengI\",\"doi\":\"10.1109/CEIDP.1991.763378\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Depolarization currents in a larger number of virgin and aged polymer-insulated medium-voltage cables have been measured as a function of the magnitude of the applied electric field. In comparison with new cables some service-aged cables revealed unusual dielectric properties. As expected, unaged cables show a lineal relation between the depolarization current and the polarizing field at moderate electric field strengths. In contrast, for many service-aged cables a more than proportional increase of the depolarization current with the applied electric field was observed (indicating some nonlinearity). Visual inspection of the cables showed a very high density of bow-tie trees in the 'non-linear' cables. Furthermore, it was observed that the nonlinearity vanished when the cable was dried and reappeared again after wetting the cable. As a conclusion from these observations, it is believed that the non-linear dielectric behaviour is a consequence of the presence of bow-tie trees in the cables. In our opinion it may be worthwhile considering the measurement of depolarization currents as a diagnostic measurement technique to detect water trees in buried cables.\",\"PeriodicalId\":277387,\"journal\":{\"name\":\"1991 Annual Report. Conference on Electrical Insulation and Dielectric Phenomena,\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-10-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1991 Annual Report. Conference on Electrical Insulation and Dielectric Phenomena,\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.1991.763378\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1991 Annual Report. Conference on Electrical Insulation and Dielectric Phenomena,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1991.763378","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Influence of ageing on depolarization currents in polymer-insulated medium-voltage cables
Depolarization currents in a larger number of virgin and aged polymer-insulated medium-voltage cables have been measured as a function of the magnitude of the applied electric field. In comparison with new cables some service-aged cables revealed unusual dielectric properties. As expected, unaged cables show a lineal relation between the depolarization current and the polarizing field at moderate electric field strengths. In contrast, for many service-aged cables a more than proportional increase of the depolarization current with the applied electric field was observed (indicating some nonlinearity). Visual inspection of the cables showed a very high density of bow-tie trees in the 'non-linear' cables. Furthermore, it was observed that the nonlinearity vanished when the cable was dried and reappeared again after wetting the cable. As a conclusion from these observations, it is believed that the non-linear dielectric behaviour is a consequence of the presence of bow-tie trees in the cables. In our opinion it may be worthwhile considering the measurement of depolarization currents as a diagnostic measurement technique to detect water trees in buried cables.