采用静态同步串联补偿器改善电力系统电能质量

Vicky T. Kullarkar, V. Chandrakar
{"title":"采用静态同步串联补偿器改善电力系统电能质量","authors":"Vicky T. Kullarkar, V. Chandrakar","doi":"10.1109/I2CT.2017.8226286","DOIUrl":null,"url":null,"abstract":"This paper presents the performance of SSSC for power quality improvement. As nonlinear loads causes the harmonics in the system and therefore the power quality gets reduce because of these non linear load. Hence power quality is study with case I. Non linear load without SSSC & case II. Non linear load with SSSC in IEEE 9 bus system. The diode bridge rectifier is used here as non linear load. Series FACTS devices are most powerful controllers used for power flow, power quality, power oscillation damping and improving transient stability of the power system. Power quality study is carried out with Fast Fourier Transform analysis and Total Harmonic Distortions are obtained which shows the harmonics present in the system. Results are validated by using MATLAB.","PeriodicalId":343232,"journal":{"name":"2017 2nd International Conference for Convergence in Technology (I2CT)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Power quality improvement in power system by using static synchronous series compensator\",\"authors\":\"Vicky T. Kullarkar, V. Chandrakar\",\"doi\":\"10.1109/I2CT.2017.8226286\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the performance of SSSC for power quality improvement. As nonlinear loads causes the harmonics in the system and therefore the power quality gets reduce because of these non linear load. Hence power quality is study with case I. Non linear load without SSSC & case II. Non linear load with SSSC in IEEE 9 bus system. The diode bridge rectifier is used here as non linear load. Series FACTS devices are most powerful controllers used for power flow, power quality, power oscillation damping and improving transient stability of the power system. Power quality study is carried out with Fast Fourier Transform analysis and Total Harmonic Distortions are obtained which shows the harmonics present in the system. Results are validated by using MATLAB.\",\"PeriodicalId\":343232,\"journal\":{\"name\":\"2017 2nd International Conference for Convergence in Technology (I2CT)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 2nd International Conference for Convergence in Technology (I2CT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/I2CT.2017.8226286\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 2nd International Conference for Convergence in Technology (I2CT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/I2CT.2017.8226286","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

本文介绍了SSSC在改善电能质量方面的性能。由于非线性负载在系统中产生谐波,从而使系统的电能质量下降。因此,本文研究了情况一、无SSSC的非线性负载和情况二的电能质量。IEEE 9总线系统中SSSC非线性负载。这里用二极管桥式整流器作为非线性负载。FACTS系列器件是最强大的控制器,用于功率流,电能质量,功率振荡阻尼和提高电力系统的暂态稳定性。利用快速傅立叶变换分析对系统的电能质量进行了研究,得到了系统中谐波的总畸变。通过MATLAB对结果进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Power quality improvement in power system by using static synchronous series compensator
This paper presents the performance of SSSC for power quality improvement. As nonlinear loads causes the harmonics in the system and therefore the power quality gets reduce because of these non linear load. Hence power quality is study with case I. Non linear load without SSSC & case II. Non linear load with SSSC in IEEE 9 bus system. The diode bridge rectifier is used here as non linear load. Series FACTS devices are most powerful controllers used for power flow, power quality, power oscillation damping and improving transient stability of the power system. Power quality study is carried out with Fast Fourier Transform analysis and Total Harmonic Distortions are obtained which shows the harmonics present in the system. Results are validated by using MATLAB.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信