基于自适应重载轨迹的稳定裕度监测系统允许潮流辨识

N. Batseva, V. Sukhorukov, E. Gavrilov
{"title":"基于自适应重载轨迹的稳定裕度监测系统允许潮流辨识","authors":"N. Batseva, V. Sukhorukov, E. Gavrilov","doi":"10.1109/RPA51116.2020.9301735","DOIUrl":null,"url":null,"abstract":"Identification of the permissible active power flows in controlled sections (CS) of power systems (PS) is one of the important tasks solved by system operators at the stage of the short-term planning and in real-time control of a regime as in Russia as abroad. The value of the maximum allowed active power flows (MAAPF) and the emergency active power transfer limits (EAPTL) depends on various factors, for example, an ambient temperature; the generators mix at power plants; amount of load’s and generator’s active power; active power flows through adjacent CS; amount of control actions (CA) received from emergency control automation systems. When the technologist calculates the MAAPF and EAPTL values using the PS digital model (DM) corresponding to the control regime measurements, he can consider only the limited number of PS states. In addition to this, he is forced out taking into account the worst possible PS state, even if it may not occur in a real operation regime.","PeriodicalId":299510,"journal":{"name":"2020 3rd International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Permissible Power Flows Identification for the Stability Margin Monitoring System based on the Adaptive Heavy-Loaded Trajectory\",\"authors\":\"N. Batseva, V. Sukhorukov, E. Gavrilov\",\"doi\":\"10.1109/RPA51116.2020.9301735\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Identification of the permissible active power flows in controlled sections (CS) of power systems (PS) is one of the important tasks solved by system operators at the stage of the short-term planning and in real-time control of a regime as in Russia as abroad. The value of the maximum allowed active power flows (MAAPF) and the emergency active power transfer limits (EAPTL) depends on various factors, for example, an ambient temperature; the generators mix at power plants; amount of load’s and generator’s active power; active power flows through adjacent CS; amount of control actions (CA) received from emergency control automation systems. When the technologist calculates the MAAPF and EAPTL values using the PS digital model (DM) corresponding to the control regime measurements, he can consider only the limited number of PS states. In addition to this, he is forced out taking into account the worst possible PS state, even if it may not occur in a real operation regime.\",\"PeriodicalId\":299510,\"journal\":{\"name\":\"2020 3rd International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA)\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 3rd International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RPA51116.2020.9301735\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 3rd International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RPA51116.2020.9301735","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

无论是在俄罗斯还是在国外,电力系统控制段允许有功潮流的确定都是系统运营商在系统短期规划和实时控制阶段要解决的重要问题之一。最大允许有功功率流(MAAPF)和紧急有功功率传输限值(EAPTL)的值取决于各种因素,例如,环境温度;发电机在发电厂混合;负载和发电机有功功率;有功功率流经相邻的CS;从紧急控制自动化系统收到的控制动作(CA)的数量。当技术人员使用与控制状态测量相对应的PS数字模型(DM)计算MAAPF和EAPTL值时,他只能考虑有限数量的PS状态。除此之外,他还被迫考虑到最坏的PS状态,即使它可能不会在实际操作中发生。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Permissible Power Flows Identification for the Stability Margin Monitoring System based on the Adaptive Heavy-Loaded Trajectory
Identification of the permissible active power flows in controlled sections (CS) of power systems (PS) is one of the important tasks solved by system operators at the stage of the short-term planning and in real-time control of a regime as in Russia as abroad. The value of the maximum allowed active power flows (MAAPF) and the emergency active power transfer limits (EAPTL) depends on various factors, for example, an ambient temperature; the generators mix at power plants; amount of load’s and generator’s active power; active power flows through adjacent CS; amount of control actions (CA) received from emergency control automation systems. When the technologist calculates the MAAPF and EAPTL values using the PS digital model (DM) corresponding to the control regime measurements, he can consider only the limited number of PS states. In addition to this, he is forced out taking into account the worst possible PS state, even if it may not occur in a real operation regime.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信