B. Tunstall, W. Wang, Z. Cheng, M. McCormick, D. Rew
{"title":"在1 kHz至4 MHz频率范围内的体外研究中组织特性电阻抗测量的系统误差分析","authors":"B. Tunstall, W. Wang, Z. Cheng, M. McCormick, D. Rew","doi":"10.1109/IEMBS.1997.757797","DOIUrl":null,"url":null,"abstract":"This paper describes some of the important systematic errors associated with an in-vitro study, using a four electrode impedance system, into the characteristics that allow for differentiation between normal and abnormal tissues. The impact of system parameters were investigated though the use of saline-filled phantoms and tissue samples. The latter being provided as part of a 100 patient in-vitro study carried out in collaboration with the Glenfield General Hospital, Leicester, UK. It has been found necessary to provide an environment with a known, and calibrated, post sample excision period. However, the orientation of the tissue during the measurement was also found to have a large and important impact upon the measured impedance.","PeriodicalId":342750,"journal":{"name":"Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"An analysis of systematic errors in the electrical impedance measurement of tissue characteristics during an in-vitro study in the frequency range 1 kHz to 4 MHz\",\"authors\":\"B. Tunstall, W. Wang, Z. Cheng, M. McCormick, D. Rew\",\"doi\":\"10.1109/IEMBS.1997.757797\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes some of the important systematic errors associated with an in-vitro study, using a four electrode impedance system, into the characteristics that allow for differentiation between normal and abnormal tissues. The impact of system parameters were investigated though the use of saline-filled phantoms and tissue samples. The latter being provided as part of a 100 patient in-vitro study carried out in collaboration with the Glenfield General Hospital, Leicester, UK. It has been found necessary to provide an environment with a known, and calibrated, post sample excision period. However, the orientation of the tissue during the measurement was also found to have a large and important impact upon the measured impedance.\",\"PeriodicalId\":342750,\"journal\":{\"name\":\"Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-10-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.1997.757797\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1997.757797","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An analysis of systematic errors in the electrical impedance measurement of tissue characteristics during an in-vitro study in the frequency range 1 kHz to 4 MHz
This paper describes some of the important systematic errors associated with an in-vitro study, using a four electrode impedance system, into the characteristics that allow for differentiation between normal and abnormal tissues. The impact of system parameters were investigated though the use of saline-filled phantoms and tissue samples. The latter being provided as part of a 100 patient in-vitro study carried out in collaboration with the Glenfield General Hospital, Leicester, UK. It has been found necessary to provide an environment with a known, and calibrated, post sample excision period. However, the orientation of the tissue during the measurement was also found to have a large and important impact upon the measured impedance.