{"title":"啤酒发酵温度的微分中值校准方法","authors":"Yang Qingchuan, Sun Bo, Chen Gang","doi":"10.1109/ICICTA.2010.840","DOIUrl":null,"url":null,"abstract":"In embedded-distribution control system, the analogue signal under test is usually non-linear. Differential median calibration method based on four-wire platinum resistance temperature compensated constant current source is proposed in accordance with the characteristics of temperature control in the course of beer fermentation. This method can guarantee accuracy of temperature detection in a small temperature range, has an edge small amount of work, rapid detection, low-cost and high-precision. The method provide a viable solution for the detection of small-scale non-linear analog.","PeriodicalId":418904,"journal":{"name":"2010 International Conference on Intelligent Computation Technology and Automation","volume":"478 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Method of Differential Median Calibration for the Temperature of Beer Fermentation\",\"authors\":\"Yang Qingchuan, Sun Bo, Chen Gang\",\"doi\":\"10.1109/ICICTA.2010.840\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In embedded-distribution control system, the analogue signal under test is usually non-linear. Differential median calibration method based on four-wire platinum resistance temperature compensated constant current source is proposed in accordance with the characteristics of temperature control in the course of beer fermentation. This method can guarantee accuracy of temperature detection in a small temperature range, has an edge small amount of work, rapid detection, low-cost and high-precision. The method provide a viable solution for the detection of small-scale non-linear analog.\",\"PeriodicalId\":418904,\"journal\":{\"name\":\"2010 International Conference on Intelligent Computation Technology and Automation\",\"volume\":\"478 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-05-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on Intelligent Computation Technology and Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICICTA.2010.840\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on Intelligent Computation Technology and Automation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICICTA.2010.840","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Method of Differential Median Calibration for the Temperature of Beer Fermentation
In embedded-distribution control system, the analogue signal under test is usually non-linear. Differential median calibration method based on four-wire platinum resistance temperature compensated constant current source is proposed in accordance with the characteristics of temperature control in the course of beer fermentation. This method can guarantee accuracy of temperature detection in a small temperature range, has an edge small amount of work, rapid detection, low-cost and high-precision. The method provide a viable solution for the detection of small-scale non-linear analog.