{"title":"屏蔽输电线路设计中最佳屏蔽角的确定","authors":"R. Holt, T. Nguyen","doi":"10.1109/PESW.2000.847335","DOIUrl":null,"url":null,"abstract":"The paper develops a general formulation that gives expressions for the exposure distance of transmission line conductors to direct lightning strikes in terms of striking distances, conductor heights, cross-arm lengths and shielding angles. The expressions are applicable to different electrogeometric models (EGM). They provide the basis on which optimal shielding angle is determined in the design of earthwires. Constrained minimisation of the exposure distance gives the optimal value for shielding angle. The expressions are validated using the published field results. Using the general expressions developed, investigations are carried out to identify the factors on which optimal shielding angle depends and to quantify the degree of dependencies. Sensitivity of the optimal shielding angle to different EGMs is evaluated in the paper.","PeriodicalId":286352,"journal":{"name":"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Determination of optimal shielding angles in shielded transmission line design\",\"authors\":\"R. Holt, T. Nguyen\",\"doi\":\"10.1109/PESW.2000.847335\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper develops a general formulation that gives expressions for the exposure distance of transmission line conductors to direct lightning strikes in terms of striking distances, conductor heights, cross-arm lengths and shielding angles. The expressions are applicable to different electrogeometric models (EGM). They provide the basis on which optimal shielding angle is determined in the design of earthwires. Constrained minimisation of the exposure distance gives the optimal value for shielding angle. The expressions are validated using the published field results. Using the general expressions developed, investigations are carried out to identify the factors on which optimal shielding angle depends and to quantify the degree of dependencies. Sensitivity of the optimal shielding angle to different EGMs is evaluated in the paper.\",\"PeriodicalId\":286352,\"journal\":{\"name\":\"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-01-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESW.2000.847335\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESW.2000.847335","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文提出了传输线导体在直击雷击下的暴露距离的一般表达式,包括击距、导体高度、横臂长度和屏蔽角。表达式适用于不同的电几何模型(EGM)。为地线设计中确定最佳屏蔽角提供了依据。暴露距离的约束最小化给出了屏蔽角的最佳值。表达式使用发布的字段结果进行验证。利用所建立的一般表达式,进行了研究,以确定最佳屏蔽角所依赖的因素,并量化其依赖程度。本文评价了最佳屏蔽角对不同电磁干扰的灵敏度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Determination of optimal shielding angles in shielded transmission line design
The paper develops a general formulation that gives expressions for the exposure distance of transmission line conductors to direct lightning strikes in terms of striking distances, conductor heights, cross-arm lengths and shielding angles. The expressions are applicable to different electrogeometric models (EGM). They provide the basis on which optimal shielding angle is determined in the design of earthwires. Constrained minimisation of the exposure distance gives the optimal value for shielding angle. The expressions are validated using the published field results. Using the general expressions developed, investigations are carried out to identify the factors on which optimal shielding angle depends and to quantify the degree of dependencies. Sensitivity of the optimal shielding angle to different EGMs is evaluated in the paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信