改变动不平衡量的多级干罗茨真空泵降噪实验研究

Kun Liu, D. Ba, Zhichen Li, G. Du, G. Wang, Zhen-hou Zhang, Xiao-guang Gu, Pei-yin Li, Nai-heng Yang
{"title":"改变动不平衡量的多级干罗茨真空泵降噪实验研究","authors":"Kun Liu, D. Ba, Zhichen Li, G. Du, G. Wang, Zhen-hou Zhang, Xiao-guang Gu, Pei-yin Li, Nai-heng Yang","doi":"10.1109/ICIE.2010.226","DOIUrl":null,"url":null,"abstract":"Multistage dry Roots vacuum pumps (MDRVPs) are vacuum equipments widely used in IC industry. This paper analyzes the influence mechanism of dynamic unbalance to vibration and noise of rotor axis in MDRVPs, and calculates the vibration deformation of the rotor axis caused by dynamic unbalance through the finite element method. Moreover, a series of experiments on noise source identification are carried on a MDRVP sample machine varying the amount of dynamic unbalance. Through the experimental results, conclusions are drawn that the periodic incentives generated by the unbalance of rotor axis are the main attribution of vibration and noise. Therefore the noise reduces when the amount of unbalance of rotor axis deceases. However, when the allowable unbalance of the rotor axis decreases to a certain degree, aerodynamic noise generated at the outlet becomes the main noise with dominant frequency. It is true that noise of MDRVPs should be no more than 72dB, so the allowable amount of dynamic unbalance should be chosen at a moderate lever as 1.0 g•mm/kg. In that way, this conclusion offers a rule for MDRVPs design and dynamic balance operation because this lever would not only meet the demand of noise reduction but also save working hours and cost for dynamic balancing.","PeriodicalId":353239,"journal":{"name":"2010 WASE International Conference on Information Engineering","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Experimental Study on Noise Reduction of Multistage Dry Roots Vacuum Pump Varying the Amount of Dynamic Unbalance\",\"authors\":\"Kun Liu, D. Ba, Zhichen Li, G. Du, G. Wang, Zhen-hou Zhang, Xiao-guang Gu, Pei-yin Li, Nai-heng Yang\",\"doi\":\"10.1109/ICIE.2010.226\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Multistage dry Roots vacuum pumps (MDRVPs) are vacuum equipments widely used in IC industry. This paper analyzes the influence mechanism of dynamic unbalance to vibration and noise of rotor axis in MDRVPs, and calculates the vibration deformation of the rotor axis caused by dynamic unbalance through the finite element method. Moreover, a series of experiments on noise source identification are carried on a MDRVP sample machine varying the amount of dynamic unbalance. Through the experimental results, conclusions are drawn that the periodic incentives generated by the unbalance of rotor axis are the main attribution of vibration and noise. Therefore the noise reduces when the amount of unbalance of rotor axis deceases. However, when the allowable unbalance of the rotor axis decreases to a certain degree, aerodynamic noise generated at the outlet becomes the main noise with dominant frequency. It is true that noise of MDRVPs should be no more than 72dB, so the allowable amount of dynamic unbalance should be chosen at a moderate lever as 1.0 g•mm/kg. In that way, this conclusion offers a rule for MDRVPs design and dynamic balance operation because this lever would not only meet the demand of noise reduction but also save working hours and cost for dynamic balancing.\",\"PeriodicalId\":353239,\"journal\":{\"name\":\"2010 WASE International Conference on Information Engineering\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-08-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 WASE International Conference on Information Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIE.2010.226\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 WASE International Conference on Information Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIE.2010.226","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

多级干式罗茨真空泵(MDRVPs)是集成电路工业中广泛应用的真空设备。分析了动不平衡对mdrvp转子轴振动和噪声的影响机理,并通过有限元法计算了动不平衡引起的转子轴振动变形。在动态不平衡量不同的MDRVP样机上进行了一系列噪声源识别实验。通过实验结果,得出了转子轴不平衡产生的周期性激励是产生振动和噪声的主要原因。因此,随着转子轴不平衡量的减小,噪声也随之降低。然而,当转子轴的允许不平衡减小到一定程度时,出口产生的气动噪声成为占主导频率的主要噪声。MDRVPs的噪声不应超过72dB,因此动态不平衡允许量应选择在1.0 g•mm/kg的中等水平。这一结论对mdrvp的设计和动平衡操作具有一定的指导意义,因为该杠杆既能满足降噪的要求,又能节省动平衡的工时和成本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental Study on Noise Reduction of Multistage Dry Roots Vacuum Pump Varying the Amount of Dynamic Unbalance
Multistage dry Roots vacuum pumps (MDRVPs) are vacuum equipments widely used in IC industry. This paper analyzes the influence mechanism of dynamic unbalance to vibration and noise of rotor axis in MDRVPs, and calculates the vibration deformation of the rotor axis caused by dynamic unbalance through the finite element method. Moreover, a series of experiments on noise source identification are carried on a MDRVP sample machine varying the amount of dynamic unbalance. Through the experimental results, conclusions are drawn that the periodic incentives generated by the unbalance of rotor axis are the main attribution of vibration and noise. Therefore the noise reduces when the amount of unbalance of rotor axis deceases. However, when the allowable unbalance of the rotor axis decreases to a certain degree, aerodynamic noise generated at the outlet becomes the main noise with dominant frequency. It is true that noise of MDRVPs should be no more than 72dB, so the allowable amount of dynamic unbalance should be chosen at a moderate lever as 1.0 g•mm/kg. In that way, this conclusion offers a rule for MDRVPs design and dynamic balance operation because this lever would not only meet the demand of noise reduction but also save working hours and cost for dynamic balancing.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信