涉及并网逆变器的可再生能源系统不稳定性

M. Cespedes, Jian Sun
{"title":"涉及并网逆变器的可再生能源系统不稳定性","authors":"M. Cespedes, Jian Sun","doi":"10.1109/APEC.2009.4802943","DOIUrl":null,"url":null,"abstract":"This paper presents a study of renewable energy system stability based on impedance models of the sources and the grid. The focus is grid-parallel inverters controlled in the current injection mode. System stability analysis based on source output impedance and load input impedance is generalized to current-source systems. Output impedance modeling of current-controlled PWM inverters for grid interface of renewable sources is presented to provide the necessary impedance models for system stability analysis. The effects of current control loop design and output filter configurations on the inverter output impedance are considered. A practical method to measure grid impedance using a frequency analyzer is presented, and the associated difficulties due to the presence of harmonics in the grid voltage are discussed. An example system involving a single-phase grid-connected inverter is presented to demonstrate the application of the proposed system analysis method.","PeriodicalId":200366,"journal":{"name":"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"83","resultStr":"{\"title\":\"Renewable Energy Systems Instability Involving Grid-Parallel Inverters\",\"authors\":\"M. Cespedes, Jian Sun\",\"doi\":\"10.1109/APEC.2009.4802943\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a study of renewable energy system stability based on impedance models of the sources and the grid. The focus is grid-parallel inverters controlled in the current injection mode. System stability analysis based on source output impedance and load input impedance is generalized to current-source systems. Output impedance modeling of current-controlled PWM inverters for grid interface of renewable sources is presented to provide the necessary impedance models for system stability analysis. The effects of current control loop design and output filter configurations on the inverter output impedance are considered. A practical method to measure grid impedance using a frequency analyzer is presented, and the associated difficulties due to the presence of harmonics in the grid voltage are discussed. An example system involving a single-phase grid-connected inverter is presented to demonstrate the application of the proposed system analysis method.\",\"PeriodicalId\":200366,\"journal\":{\"name\":\"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-03-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"83\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.2009.4802943\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.2009.4802943","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 83

摘要

本文提出了一种基于电源和电网阻抗模型的可再生能源系统稳定性研究方法。重点研究了以电流注入方式控制的并网逆变器。将基于源输出阻抗和负载输入阻抗的系统稳定性分析推广到电流源系统。提出了可再生能源电网接口电流控制PWM逆变器的输出阻抗建模方法,为系统稳定性分析提供了必要的阻抗模型。考虑了电流控制环设计和输出滤波器配置对逆变器输出阻抗的影响。提出了一种用频率分析仪测量电网阻抗的实用方法,并讨论了由于电网电压中存在谐波而引起的相关困难。最后以一个单相并网逆变器系统为例,说明了所提出的系统分析方法的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Renewable Energy Systems Instability Involving Grid-Parallel Inverters
This paper presents a study of renewable energy system stability based on impedance models of the sources and the grid. The focus is grid-parallel inverters controlled in the current injection mode. System stability analysis based on source output impedance and load input impedance is generalized to current-source systems. Output impedance modeling of current-controlled PWM inverters for grid interface of renewable sources is presented to provide the necessary impedance models for system stability analysis. The effects of current control loop design and output filter configurations on the inverter output impedance are considered. A practical method to measure grid impedance using a frequency analyzer is presented, and the associated difficulties due to the presence of harmonics in the grid voltage are discussed. An example system involving a single-phase grid-connected inverter is presented to demonstrate the application of the proposed system analysis method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信