P. Portillo-Caurcel, S. Ibarmia, M. Benito-Parejo, J. Mas-Hesse, A. Balado, A. Martindale, J. Pearson, G. Butcher, C. Feldman, E. Bunce
{"title":"bepicolcolombo的MIXS仪器的Geant4全模型验证","authors":"P. Portillo-Caurcel, S. Ibarmia, M. Benito-Parejo, J. Mas-Hesse, A. Balado, A. Martindale, J. Pearson, G. Butcher, C. Feldman, E. Bunce","doi":"10.1109/RADECS.2017.8696223","DOIUrl":null,"url":null,"abstract":"A full Geant4 model for the BepiColombo MIXS X-ray telescope has been implemented in order to simulate the propagation of fluorescence X-rays through a state-of-the-art micro channel optics (MCP). Our model includes a realistic 3D geometrical description of the instrument, down to micrometer scale for the optics, as well as the physics processes for the reflection of X-ray photons at grazing angles combined with the standard Geant4 electromagnetic interactions. The model has been preliminary validated against design reference simulation software and with experimental test data.","PeriodicalId":223580,"journal":{"name":"2017 17th European Conference on Radiation and Its Effects on Components and Systems (RADECS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of a Geant4 full model for the MIXS instrument at BepiColombo\",\"authors\":\"P. Portillo-Caurcel, S. Ibarmia, M. Benito-Parejo, J. Mas-Hesse, A. Balado, A. Martindale, J. Pearson, G. Butcher, C. Feldman, E. Bunce\",\"doi\":\"10.1109/RADECS.2017.8696223\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A full Geant4 model for the BepiColombo MIXS X-ray telescope has been implemented in order to simulate the propagation of fluorescence X-rays through a state-of-the-art micro channel optics (MCP). Our model includes a realistic 3D geometrical description of the instrument, down to micrometer scale for the optics, as well as the physics processes for the reflection of X-ray photons at grazing angles combined with the standard Geant4 electromagnetic interactions. The model has been preliminary validated against design reference simulation software and with experimental test data.\",\"PeriodicalId\":223580,\"journal\":{\"name\":\"2017 17th European Conference on Radiation and Its Effects on Components and Systems (RADECS)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 17th European Conference on Radiation and Its Effects on Components and Systems (RADECS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RADECS.2017.8696223\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 17th European Conference on Radiation and Its Effects on Components and Systems (RADECS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RADECS.2017.8696223","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Validation of a Geant4 full model for the MIXS instrument at BepiColombo
A full Geant4 model for the BepiColombo MIXS X-ray telescope has been implemented in order to simulate the propagation of fluorescence X-rays through a state-of-the-art micro channel optics (MCP). Our model includes a realistic 3D geometrical description of the instrument, down to micrometer scale for the optics, as well as the physics processes for the reflection of X-ray photons at grazing angles combined with the standard Geant4 electromagnetic interactions. The model has been preliminary validated against design reference simulation software and with experimental test data.