{"title":"用负压脉冲识别人体呼吸系统气动参数","authors":"P. Piwowar","doi":"10.1109/IMTC.2004.1351367","DOIUrl":null,"url":null,"abstract":"This paper presents results of experiments with the identification of pneumatic parameters for the five models of human flow during artificially caused transient states. These transient states are caused by short-time negative pulses, which are generated at the outlet of the patient's air-ducts. In this paper is shown the influence of the non-linear character of the model on the respiratory system parameter identification results.","PeriodicalId":386903,"journal":{"name":"Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510)","volume":"12 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Identification of pneumatic parameters of the human respiratory system by negative pressure impulses\",\"authors\":\"P. Piwowar\",\"doi\":\"10.1109/IMTC.2004.1351367\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents results of experiments with the identification of pneumatic parameters for the five models of human flow during artificially caused transient states. These transient states are caused by short-time negative pulses, which are generated at the outlet of the patient's air-ducts. In this paper is shown the influence of the non-linear character of the model on the respiratory system parameter identification results.\",\"PeriodicalId\":386903,\"journal\":{\"name\":\"Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510)\",\"volume\":\"12 3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-05-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMTC.2004.1351367\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.2004.1351367","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Identification of pneumatic parameters of the human respiratory system by negative pressure impulses
This paper presents results of experiments with the identification of pneumatic parameters for the five models of human flow during artificially caused transient states. These transient states are caused by short-time negative pulses, which are generated at the outlet of the patient's air-ducts. In this paper is shown the influence of the non-linear character of the model on the respiratory system parameter identification results.