使用紧凑混响室测量WiFi设备的总辐射功率

V. Monebhurrun, T. Letertre
{"title":"使用紧凑混响室测量WiFi设备的总辐射功率","authors":"V. Monebhurrun, T. Letertre","doi":"10.1109/EMCZUR.2009.4783391","DOIUrl":null,"url":null,"abstract":"A compact reverberation chamber is herein considered for the TRP (Total Radiated Power) measurements of WiFi devices. An immediate difficulty when testing WiFi devices is the lack of a standard emulator which allows robust control of the emitted signal for power measurement purposes. The average power delivered by a WiFi device depends upon the data rate which itself can also vary during time. Multipath environments also influence the data rate and the signal delivered by the device. The procedure proposed herein is developed in order to ensure repeatable measurements. The mechanical stirring of the reverberation chamber is optimized to enable fast measurements.","PeriodicalId":192851,"journal":{"name":"2009 20th International Zurich Symposium on Electromagnetic Compatibility","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Total radiated power measurements of WiFi devices using a compact reverberation chamber\",\"authors\":\"V. Monebhurrun, T. Letertre\",\"doi\":\"10.1109/EMCZUR.2009.4783391\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A compact reverberation chamber is herein considered for the TRP (Total Radiated Power) measurements of WiFi devices. An immediate difficulty when testing WiFi devices is the lack of a standard emulator which allows robust control of the emitted signal for power measurement purposes. The average power delivered by a WiFi device depends upon the data rate which itself can also vary during time. Multipath environments also influence the data rate and the signal delivered by the device. The procedure proposed herein is developed in order to ensure repeatable measurements. The mechanical stirring of the reverberation chamber is optimized to enable fast measurements.\",\"PeriodicalId\":192851,\"journal\":{\"name\":\"2009 20th International Zurich Symposium on Electromagnetic Compatibility\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-02-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 20th International Zurich Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMCZUR.2009.4783391\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 20th International Zurich Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCZUR.2009.4783391","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

本文考虑了一个紧凑的混响室用于WiFi设备的TRP(总辐射功率)测量。在测试WiFi设备时,一个直接的困难是缺乏一个标准的模拟器,该模拟器允许对发射信号进行鲁棒控制,以用于功率测量。WiFi设备传输的平均功率取决于数据速率,数据速率本身也会随着时间的推移而变化。多路径环境也会影响设备传输的数据速率和信号。本文提出的程序是为了确保可重复的测量。混响室的机械搅拌经过优化,可实现快速测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Total radiated power measurements of WiFi devices using a compact reverberation chamber
A compact reverberation chamber is herein considered for the TRP (Total Radiated Power) measurements of WiFi devices. An immediate difficulty when testing WiFi devices is the lack of a standard emulator which allows robust control of the emitted signal for power measurement purposes. The average power delivered by a WiFi device depends upon the data rate which itself can also vary during time. Multipath environments also influence the data rate and the signal delivered by the device. The procedure proposed herein is developed in order to ensure repeatable measurements. The mechanical stirring of the reverberation chamber is optimized to enable fast measurements.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信