确定振声域信号质量系数的第一阶段分析:波形完整性分析

M. C. Arva
{"title":"确定振声域信号质量系数的第一阶段分析:波形完整性分析","authors":"M. C. Arva","doi":"10.1109/ECAI.2016.7861126","DOIUrl":null,"url":null,"abstract":"This paper presents the first stage of the analysis on determining the Signal Quality Coefficient in the vibro-acoustic domain. This stage is mandatory in order to determine if two analog signals, one considered “target” and the other “reference”, have a certain amount of similarity and the “target” waveform maintain its integrity reported to the “reference” waveform. This analysis can be used for diagnosis of conditioning circuits of the vibro-acoustic data acquisition systems in order to verify the analogic signals passing through the preconditioning circuits of the AD converters. A cross-correlation algorithm is used to quantify the integrity of the “target” signal respect to the “reference” signal. This waveform integrity analysis is referred to as a time analysis and its result returns the value of integrity coefficient.","PeriodicalId":122809,"journal":{"name":"2016 8th International Conference on Electronics, Computers and Artificial Intelligence (ECAI)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"First stage analysis on determining the signal quality coefficient in vibro-acoustic domain: Waveform integrity analysis\",\"authors\":\"M. C. Arva\",\"doi\":\"10.1109/ECAI.2016.7861126\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the first stage of the analysis on determining the Signal Quality Coefficient in the vibro-acoustic domain. This stage is mandatory in order to determine if two analog signals, one considered “target” and the other “reference”, have a certain amount of similarity and the “target” waveform maintain its integrity reported to the “reference” waveform. This analysis can be used for diagnosis of conditioning circuits of the vibro-acoustic data acquisition systems in order to verify the analogic signals passing through the preconditioning circuits of the AD converters. A cross-correlation algorithm is used to quantify the integrity of the “target” signal respect to the “reference” signal. This waveform integrity analysis is referred to as a time analysis and its result returns the value of integrity coefficient.\",\"PeriodicalId\":122809,\"journal\":{\"name\":\"2016 8th International Conference on Electronics, Computers and Artificial Intelligence (ECAI)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 8th International Conference on Electronics, Computers and Artificial Intelligence (ECAI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECAI.2016.7861126\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 8th International Conference on Electronics, Computers and Artificial Intelligence (ECAI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECAI.2016.7861126","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了振动声域信号质量系数确定分析的第一阶段。这一阶段是强制性的,目的是确定两个模拟信号,一个被认为是“目标”,另一个被认为是“参考”,是否具有一定的相似性,以及“目标”波形是否保持向“参考”波形报告的完整性。该分析可用于振动声数据采集系统调理电路的诊断,以验证通过AD转换器预处理电路的模拟信号。互相关算法用于量化“目标”信号相对于“参考”信号的完整性。这种波形完整性分析被称为时间分析,其结果返回完整性系数的值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
First stage analysis on determining the signal quality coefficient in vibro-acoustic domain: Waveform integrity analysis
This paper presents the first stage of the analysis on determining the Signal Quality Coefficient in the vibro-acoustic domain. This stage is mandatory in order to determine if two analog signals, one considered “target” and the other “reference”, have a certain amount of similarity and the “target” waveform maintain its integrity reported to the “reference” waveform. This analysis can be used for diagnosis of conditioning circuits of the vibro-acoustic data acquisition systems in order to verify the analogic signals passing through the preconditioning circuits of the AD converters. A cross-correlation algorithm is used to quantify the integrity of the “target” signal respect to the “reference” signal. This waveform integrity analysis is referred to as a time analysis and its result returns the value of integrity coefficient.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信