Andrew J. A. Smith, A. Roddie, P. Woolliams
{"title":"共面到同轴转换的电光采样提高了快速示波器的校准","authors":"Andrew J. A. Smith, A. Roddie, P. Woolliams","doi":"10.1109/ARFTG.2000.327439","DOIUrl":null,"url":null,"abstract":"Improvements to the NPL time domain measurement facility for the calibration of fast oscilloscope risetime are described. Particular emphasis is placed on characterising a coplanar waveguide to coaxial connector transition between a photoconductive pulse generator and the input of an oscilloscope sampling head. Two methods of measuring the transition are described and it is shown that test electrical pulses of less than 4 ps width can be applied to the oscilloscope.","PeriodicalId":166771,"journal":{"name":"56th ARFTG Conference Digest","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Electro-optic sampling of coplanar to coaxial transitions to enhance the calibration of fast oscilloscopes\",\"authors\":\"Andrew J. A. Smith, A. Roddie, P. Woolliams\",\"doi\":\"10.1109/ARFTG.2000.327439\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Improvements to the NPL time domain measurement facility for the calibration of fast oscilloscope risetime are described. Particular emphasis is placed on characterising a coplanar waveguide to coaxial connector transition between a photoconductive pulse generator and the input of an oscilloscope sampling head. Two methods of measuring the transition are described and it is shown that test electrical pulses of less than 4 ps width can be applied to the oscilloscope.\",\"PeriodicalId\":166771,\"journal\":{\"name\":\"56th ARFTG Conference Digest\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"56th ARFTG Conference Digest\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ARFTG.2000.327439\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"56th ARFTG Conference Digest","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ARFTG.2000.327439","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

描述了对NPL时域测量设备的改进,以校准快速示波器上升时间。特别强调的是表征在光导脉冲发生器和示波器采样头输入之间的共面波导到同轴连接器的过渡。描述了两种测量跃迁的方法,并证明了测试宽度小于4ps的电脉冲可以应用于示波器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electro-optic sampling of coplanar to coaxial transitions to enhance the calibration of fast oscilloscopes
Improvements to the NPL time domain measurement facility for the calibration of fast oscilloscope risetime are described. Particular emphasis is placed on characterising a coplanar waveguide to coaxial connector transition between a photoconductive pulse generator and the input of an oscilloscope sampling head. Two methods of measuring the transition are described and it is shown that test electrical pulses of less than 4 ps width can be applied to the oscilloscope.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信