心脏起搏器的无线能量传输

Umeshika Uthayakumar, Yasanthi Jayaweera
{"title":"心脏起搏器的无线能量传输","authors":"Umeshika Uthayakumar, Yasanthi Jayaweera","doi":"10.1109/ISWTA55313.2022.9942779","DOIUrl":null,"url":null,"abstract":"Cardiac pacemaker is an electronic device used to regulate the heartbeat of patients suffering with congenital heart defects. Considering the limitations in lifespan of current cardiac pacemaker battery, a wireless charging mechanism for cardiac pacemaker is proposed in this paper. Circuitry model and electromagnetic geometry is developed using Ansys Maxwell and Ansys High-Frequency Structure Simulator (HFSS) software to analyze three main technical issues such as: implantation, efficiency and safety. Specific Absorption Rate (SAR) and induced electric field in a 3-D model human body is evaluated by numerical analysis and simulation to ensure that the developed system adheres to safety limits proposed by Institute of Electrical and Electronics Engineers (IEEE) standard and International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines.","PeriodicalId":293957,"journal":{"name":"2022 IEEE Symposium on Wireless Technology & Applications (ISWTA)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Wireless Power Transfer for Cardiac Pacemaker\",\"authors\":\"Umeshika Uthayakumar, Yasanthi Jayaweera\",\"doi\":\"10.1109/ISWTA55313.2022.9942779\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cardiac pacemaker is an electronic device used to regulate the heartbeat of patients suffering with congenital heart defects. Considering the limitations in lifespan of current cardiac pacemaker battery, a wireless charging mechanism for cardiac pacemaker is proposed in this paper. Circuitry model and electromagnetic geometry is developed using Ansys Maxwell and Ansys High-Frequency Structure Simulator (HFSS) software to analyze three main technical issues such as: implantation, efficiency and safety. Specific Absorption Rate (SAR) and induced electric field in a 3-D model human body is evaluated by numerical analysis and simulation to ensure that the developed system adheres to safety limits proposed by Institute of Electrical and Electronics Engineers (IEEE) standard and International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines.\",\"PeriodicalId\":293957,\"journal\":{\"name\":\"2022 IEEE Symposium on Wireless Technology & Applications (ISWTA)\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE Symposium on Wireless Technology & Applications (ISWTA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISWTA55313.2022.9942779\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Symposium on Wireless Technology & Applications (ISWTA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISWTA55313.2022.9942779","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

心脏起搏器是一种电子装置,用于调节患有先天性心脏缺陷的患者的心跳。针对目前心脏起搏器电池寿命有限的问题,提出了一种心脏起搏器无线充电机制。利用Ansys Maxwell和Ansys高频结构模拟器(HFSS)软件建立电路模型和电磁几何,分析了植入、效率和安全性三个主要技术问题。通过数值分析和模拟对三维人体模型的比吸收率(SAR)和感应电场进行了评估,以确保开发的系统符合电气和电子工程师协会(IEEE)标准和国际非电离辐射防护委员会(ICNIRP)指南提出的安全限制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Wireless Power Transfer for Cardiac Pacemaker
Cardiac pacemaker is an electronic device used to regulate the heartbeat of patients suffering with congenital heart defects. Considering the limitations in lifespan of current cardiac pacemaker battery, a wireless charging mechanism for cardiac pacemaker is proposed in this paper. Circuitry model and electromagnetic geometry is developed using Ansys Maxwell and Ansys High-Frequency Structure Simulator (HFSS) software to analyze three main technical issues such as: implantation, efficiency and safety. Specific Absorption Rate (SAR) and induced electric field in a 3-D model human body is evaluated by numerical analysis and simulation to ensure that the developed system adheres to safety limits proposed by Institute of Electrical and Electronics Engineers (IEEE) standard and International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信