j型屈服座的有限元分析

Muhammad Shahiq, M. Z. Iqbal
{"title":"j型屈服座的有限元分析","authors":"Muhammad Shahiq, M. Z. Iqbal","doi":"10.1109/ICET.2016.7813233","DOIUrl":null,"url":null,"abstract":"Safety of structures from shocks is a critical problem in accidents such as crashing of automobiles, earthquakes and explosions. Yield mounts/isolators are used to isolate the propagation of such shocks from source to target. “J-mount” is an example of yield mounts. In this research, shock absorbing performance of a “J-mount” type “3A” is evaluated using Finite element analysis (FEA). Explicit Dynamics module of ANSYS was used to perform FEA. Shock inputs ranging from 40-160 g were applied to “J-mount.” As a result, Von Mises stresses, total deformation, shock transmitted and efficiency of “J-mount” were plotted for the whole range of shock loading. It was found that maximum efficiency of “3A” type “J-mount” occurs at a shock value of 100g and it failed to damp shock when shock value becomes 160g.","PeriodicalId":285090,"journal":{"name":"2016 International Conference on Emerging Technologies (ICET)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"FEA analysis of a J-type yielding mount\",\"authors\":\"Muhammad Shahiq, M. Z. Iqbal\",\"doi\":\"10.1109/ICET.2016.7813233\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Safety of structures from shocks is a critical problem in accidents such as crashing of automobiles, earthquakes and explosions. Yield mounts/isolators are used to isolate the propagation of such shocks from source to target. “J-mount” is an example of yield mounts. In this research, shock absorbing performance of a “J-mount” type “3A” is evaluated using Finite element analysis (FEA). Explicit Dynamics module of ANSYS was used to perform FEA. Shock inputs ranging from 40-160 g were applied to “J-mount.” As a result, Von Mises stresses, total deformation, shock transmitted and efficiency of “J-mount” were plotted for the whole range of shock loading. It was found that maximum efficiency of “3A” type “J-mount” occurs at a shock value of 100g and it failed to damp shock when shock value becomes 160g.\",\"PeriodicalId\":285090,\"journal\":{\"name\":\"2016 International Conference on Emerging Technologies (ICET)\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 International Conference on Emerging Technologies (ICET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICET.2016.7813233\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Conference on Emerging Technologies (ICET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICET.2016.7813233","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在汽车碰撞、地震和爆炸等事故中,结构的抗冲击安全是一个关键问题。产量支架/隔离器用于隔离这种冲击从源到目标的传播。“J-mount”是产量mount的一个例子。在这项研究中,使用有限元分析(FEA)评估了“j”型“3A”的减震性能。采用ANSYS的显式动力学模块进行有限元分析。冲击输入范围从40-160克应用于“J-mount”。绘制了冲击载荷全范围内的Von Mises应力、总变形、冲击传递和“j”座效率。发现“3A”型“j”座在冲击值为100g时效率达到最大值,当冲击值为160g时不能阻尼冲击。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
FEA analysis of a J-type yielding mount
Safety of structures from shocks is a critical problem in accidents such as crashing of automobiles, earthquakes and explosions. Yield mounts/isolators are used to isolate the propagation of such shocks from source to target. “J-mount” is an example of yield mounts. In this research, shock absorbing performance of a “J-mount” type “3A” is evaluated using Finite element analysis (FEA). Explicit Dynamics module of ANSYS was used to perform FEA. Shock inputs ranging from 40-160 g were applied to “J-mount.” As a result, Von Mises stresses, total deformation, shock transmitted and efficiency of “J-mount” were plotted for the whole range of shock loading. It was found that maximum efficiency of “3A” type “J-mount” occurs at a shock value of 100g and it failed to damp shock when shock value becomes 160g.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信