H. Koay, A. R. Ruslinda, S. S. B. Hashwan, M. F. Fatin, V. Thivina, V. Tony, M. K. Md Arshad, C. Voon, U. Hashim
{"title":"用于生物传感应用的还原氧化石墨烯-碳纳米管杂化膜的表面形貌","authors":"H. Koay, A. R. Ruslinda, S. S. B. Hashwan, M. F. Fatin, V. Thivina, V. Tony, M. K. Md Arshad, C. Voon, U. Hashim","doi":"10.1109/SMELEC.2016.7573656","DOIUrl":null,"url":null,"abstract":"Graphene is one of the carbon allotropes that possesses several outstanding properties which is suitable to be used in bio-sensing applications. Reduction of graphene oxide (GO) is the main concern of researchers in preparing better quality of graphene at a lower cost with mass production as the reduced GO partially restores the pristine graphene. The reduced graphene oxide (rGO) is then mixed with multi-walled carbon nanotubes (MWCNTs) to form the three-dimensional arrangement of rGO-CNTs hybrid nanocomposite which can overcome the limitations faced while using rGO or MWCNTs separately in bio-sensing applications. Here we demonstrate the sample preparation of rGO-CNTs hybrid film for biosensing applications. GO was prepared by modified Hummer's method and rGO was obtained by reducing GO with L-ascorbic acid. The characterizations of rGO-CNTs hybrid film were examined via Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM) and Fourier Transform Infrared Spectroscopy (FTIR). The surface morphologies of GO, MWCNTs, GO-CNTs hybrid and rGO-CNTs hybrid films were observed via SEM. The thickness and the surface roughness of MWCNTs, GO, GO-CNTs hybrid and rGO-CNTs hybrid films were examined via AFM. FTIR was carried out to examine the carboxyl functional group in the rGO-CNTs hybrid film.","PeriodicalId":169983,"journal":{"name":"2016 IEEE International Conference on Semiconductor Electronics (ICSE)","volume":"2017 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Surface morphology of reduced graphene oxide-carbon nanotubes hybrid film for bio-sensing applications\",\"authors\":\"H. Koay, A. R. Ruslinda, S. S. B. Hashwan, M. F. Fatin, V. Thivina, V. Tony, M. K. Md Arshad, C. Voon, U. Hashim\",\"doi\":\"10.1109/SMELEC.2016.7573656\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Graphene is one of the carbon allotropes that possesses several outstanding properties which is suitable to be used in bio-sensing applications. Reduction of graphene oxide (GO) is the main concern of researchers in preparing better quality of graphene at a lower cost with mass production as the reduced GO partially restores the pristine graphene. The reduced graphene oxide (rGO) is then mixed with multi-walled carbon nanotubes (MWCNTs) to form the three-dimensional arrangement of rGO-CNTs hybrid nanocomposite which can overcome the limitations faced while using rGO or MWCNTs separately in bio-sensing applications. Here we demonstrate the sample preparation of rGO-CNTs hybrid film for biosensing applications. GO was prepared by modified Hummer's method and rGO was obtained by reducing GO with L-ascorbic acid. The characterizations of rGO-CNTs hybrid film were examined via Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM) and Fourier Transform Infrared Spectroscopy (FTIR). The surface morphologies of GO, MWCNTs, GO-CNTs hybrid and rGO-CNTs hybrid films were observed via SEM. The thickness and the surface roughness of MWCNTs, GO, GO-CNTs hybrid and rGO-CNTs hybrid films were examined via AFM. FTIR was carried out to examine the carboxyl functional group in the rGO-CNTs hybrid film.\",\"PeriodicalId\":169983,\"journal\":{\"name\":\"2016 IEEE International Conference on Semiconductor Electronics (ICSE)\",\"volume\":\"2017 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE International Conference on Semiconductor Electronics (ICSE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SMELEC.2016.7573656\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Conference on Semiconductor Electronics (ICSE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SMELEC.2016.7573656","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Surface morphology of reduced graphene oxide-carbon nanotubes hybrid film for bio-sensing applications
Graphene is one of the carbon allotropes that possesses several outstanding properties which is suitable to be used in bio-sensing applications. Reduction of graphene oxide (GO) is the main concern of researchers in preparing better quality of graphene at a lower cost with mass production as the reduced GO partially restores the pristine graphene. The reduced graphene oxide (rGO) is then mixed with multi-walled carbon nanotubes (MWCNTs) to form the three-dimensional arrangement of rGO-CNTs hybrid nanocomposite which can overcome the limitations faced while using rGO or MWCNTs separately in bio-sensing applications. Here we demonstrate the sample preparation of rGO-CNTs hybrid film for biosensing applications. GO was prepared by modified Hummer's method and rGO was obtained by reducing GO with L-ascorbic acid. The characterizations of rGO-CNTs hybrid film were examined via Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM) and Fourier Transform Infrared Spectroscopy (FTIR). The surface morphologies of GO, MWCNTs, GO-CNTs hybrid and rGO-CNTs hybrid films were observed via SEM. The thickness and the surface roughness of MWCNTs, GO, GO-CNTs hybrid and rGO-CNTs hybrid films were examined via AFM. FTIR was carried out to examine the carboxyl functional group in the rGO-CNTs hybrid film.