基于delta-sigma的A/D转换降低可再生能源系统并网逆变器中的低次均匀谐波

Tobias Barth, Martin Wagner, S. Bernet
{"title":"基于delta-sigma的A/D转换降低可再生能源系统并网逆变器中的低次均匀谐波","authors":"Tobias Barth, Martin Wagner, S. Bernet","doi":"10.1109/SSD.2014.6808868","DOIUrl":null,"url":null,"abstract":"Measurement of current and voltage is an important part of an overall converter system. Especially the input signals for the control systems have to be measured with best accuracy to get a proper control result. This paper compares low order even harmonics in the case of a sample-and-hold based analog-to-digital conversion to harmonics with delta-sigma-modulation based analog-to-digital conversion. It is shown that delta-sigma-based analog-to-digital conversion results in a reduction of low order harmonics driven by the measured current and voltage signal with aliasing effects. The resulting harmonics not depending on the switching frequency of the system and are lower than the limits given by IEEE1547.","PeriodicalId":168063,"journal":{"name":"2014 IEEE 11th International Multi-Conference on Systems, Signals & Devices (SSD14)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reduction of low-order-even-harmonics in grid connected inverters for renewable energy systems using delta-sigma based A/D conversion\",\"authors\":\"Tobias Barth, Martin Wagner, S. Bernet\",\"doi\":\"10.1109/SSD.2014.6808868\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measurement of current and voltage is an important part of an overall converter system. Especially the input signals for the control systems have to be measured with best accuracy to get a proper control result. This paper compares low order even harmonics in the case of a sample-and-hold based analog-to-digital conversion to harmonics with delta-sigma-modulation based analog-to-digital conversion. It is shown that delta-sigma-based analog-to-digital conversion results in a reduction of low order harmonics driven by the measured current and voltage signal with aliasing effects. The resulting harmonics not depending on the switching frequency of the system and are lower than the limits given by IEEE1547.\",\"PeriodicalId\":168063,\"journal\":{\"name\":\"2014 IEEE 11th International Multi-Conference on Systems, Signals & Devices (SSD14)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE 11th International Multi-Conference on Systems, Signals & Devices (SSD14)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SSD.2014.6808868\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE 11th International Multi-Conference on Systems, Signals & Devices (SSD14)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SSD.2014.6808868","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电流和电压的测量是整个变换器系统的重要组成部分。特别是对控制系统的输入信号进行高精度测量,以获得理想的控制效果。本文比较了基于采样保持的模数转换的低阶均匀谐波与基于δ -sigma调制的模数转换的谐波。结果表明,基于δ - σ的模数转换可以降低由被测电流和电压信号驱动的低阶谐波,并具有混叠效应。产生的谐波不依赖于系统的开关频率,并且低于IEEE1547给出的限值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reduction of low-order-even-harmonics in grid connected inverters for renewable energy systems using delta-sigma based A/D conversion
Measurement of current and voltage is an important part of an overall converter system. Especially the input signals for the control systems have to be measured with best accuracy to get a proper control result. This paper compares low order even harmonics in the case of a sample-and-hold based analog-to-digital conversion to harmonics with delta-sigma-modulation based analog-to-digital conversion. It is shown that delta-sigma-based analog-to-digital conversion results in a reduction of low order harmonics driven by the measured current and voltage signal with aliasing effects. The resulting harmonics not depending on the switching frequency of the system and are lower than the limits given by IEEE1547.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信