统计波动对心脏SPECT临床计数水平缺陷检出率影响的研究

M. Durbin, C. Bai, Jinghan Ye, Z. Zhao, A. Da Silva, L. Shao
{"title":"统计波动对心脏SPECT临床计数水平缺陷检出率影响的研究","authors":"M. Durbin, C. Bai, Jinghan Ye, Z. Zhao, A. Da Silva, L. Shao","doi":"10.1109/NSSMIC.2001.1009266","DOIUrl":null,"url":null,"abstract":"Cardiac SPECT using Tl-201 suffers from low count statistics. Any statistical studies concerning the evaluation of a reconstruction algorithm, acquisition parameters, diagnostic confidence, etc., for clinical applications are impacted by the difficulty of obtaining data with multiple noise realizations. For this work, we acquired list-mode data of a Tl-201 cardiac phantom with very high counts in three configurations-with an anterior defect, an inferior defect, and no defect. The list-mode data were repartitioned to obtain statistically independent multiple data sets all with the same, clinically relevant noise level. Images were reconstructed from each of the resulting data sets using an iterative algorithm with attenuation correction. Reconstructed images were examined by four human observers, as well as analyzed quantitatively. The ability of observers to differentiate between normal scans and scans with defects varied substantially among datasets. There was correlation between the measured defect detectability and the visual assessment. The fact that the visibility of defects and the uniformity of normal scans varied significantly from one data set to the next, even when both were acquired at the same time, under identical conditions, indicates that the low statistics levels at clinical doses can have a measurable effect on diagnostic confidence.","PeriodicalId":159123,"journal":{"name":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Study of the effect of statistical fluctuations on defect detectability at clinical count levels in cardiac SPECT\",\"authors\":\"M. Durbin, C. Bai, Jinghan Ye, Z. Zhao, A. Da Silva, L. Shao\",\"doi\":\"10.1109/NSSMIC.2001.1009266\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cardiac SPECT using Tl-201 suffers from low count statistics. Any statistical studies concerning the evaluation of a reconstruction algorithm, acquisition parameters, diagnostic confidence, etc., for clinical applications are impacted by the difficulty of obtaining data with multiple noise realizations. For this work, we acquired list-mode data of a Tl-201 cardiac phantom with very high counts in three configurations-with an anterior defect, an inferior defect, and no defect. The list-mode data were repartitioned to obtain statistically independent multiple data sets all with the same, clinically relevant noise level. Images were reconstructed from each of the resulting data sets using an iterative algorithm with attenuation correction. Reconstructed images were examined by four human observers, as well as analyzed quantitatively. The ability of observers to differentiate between normal scans and scans with defects varied substantially among datasets. There was correlation between the measured defect detectability and the visual assessment. The fact that the visibility of defects and the uniformity of normal scans varied significantly from one data set to the next, even when both were acquired at the same time, under identical conditions, indicates that the low statistics levels at clinical doses can have a measurable effect on diagnostic confidence.\",\"PeriodicalId\":159123,\"journal\":{\"name\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"volume\":\"65 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2001.1009266\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2001.1009266","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

心脏SPECT使用Tl-201存在计数统计低的问题。任何关于临床应用的重建算法、采集参数、诊断置信度等评价的统计研究都受到多重噪声实现难以获得数据的影响。在这项工作中,我们获得了Tl-201心脏幻影的列表模式数据,在三种配置下具有非常高的计数-具有前侧缺陷,下侧缺陷和无缺陷。将列表模式数据重新划分,以获得具有相同临床相关噪声水平的统计独立的多个数据集。使用带衰减校正的迭代算法从每个结果数据集重建图像。重建图像由四名人类观察员检查,并进行定量分析。观察者区分正常扫描和有缺陷扫描的能力在数据集之间有很大差异。测量的缺陷可检测性与视觉评估之间存在相关性。缺陷的可见性和正常扫描的均匀性在不同的数据集之间存在显著差异,即使在相同的条件下同时获得两者,这一事实表明,临床剂量的低统计水平可以对诊断的可信度产生可测量的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study of the effect of statistical fluctuations on defect detectability at clinical count levels in cardiac SPECT
Cardiac SPECT using Tl-201 suffers from low count statistics. Any statistical studies concerning the evaluation of a reconstruction algorithm, acquisition parameters, diagnostic confidence, etc., for clinical applications are impacted by the difficulty of obtaining data with multiple noise realizations. For this work, we acquired list-mode data of a Tl-201 cardiac phantom with very high counts in three configurations-with an anterior defect, an inferior defect, and no defect. The list-mode data were repartitioned to obtain statistically independent multiple data sets all with the same, clinically relevant noise level. Images were reconstructed from each of the resulting data sets using an iterative algorithm with attenuation correction. Reconstructed images were examined by four human observers, as well as analyzed quantitatively. The ability of observers to differentiate between normal scans and scans with defects varied substantially among datasets. There was correlation between the measured defect detectability and the visual assessment. The fact that the visibility of defects and the uniformity of normal scans varied significantly from one data set to the next, even when both were acquired at the same time, under identical conditions, indicates that the low statistics levels at clinical doses can have a measurable effect on diagnostic confidence.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信