{"title":"输电系统重新配置,以进行拥塞管理,确保暂态和电压稳定","authors":"H. Ahmadi, M. Khanabadi, H. Ghasemi","doi":"10.1109/EEEIC-2.2013.6737876","DOIUrl":null,"url":null,"abstract":"Transmission congestion management has been an important issue to power system operators and planners. As of the remedial/preventive actions, transmission reconfiguration has been employed to relieve congestion. In this paper, a methodology is proposed which optimally determines the system configuration to relieve congestion while respecting system security limits such as N-1 contingency criteria, voltage limits, voltage stability margin and transient stability. Most of these important criteria have been overlooked in the previous literature. The corresponding problem is solved using Benders decomposition method. The proposed methodology is evaluated using the IEEE 300-bus test system.","PeriodicalId":445295,"journal":{"name":"2013 13th International Conference on Environment and Electrical Engineering (EEEIC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Transmission system reconfiguration for congestion management ensuring transient and voltage stability\",\"authors\":\"H. Ahmadi, M. Khanabadi, H. Ghasemi\",\"doi\":\"10.1109/EEEIC-2.2013.6737876\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Transmission congestion management has been an important issue to power system operators and planners. As of the remedial/preventive actions, transmission reconfiguration has been employed to relieve congestion. In this paper, a methodology is proposed which optimally determines the system configuration to relieve congestion while respecting system security limits such as N-1 contingency criteria, voltage limits, voltage stability margin and transient stability. Most of these important criteria have been overlooked in the previous literature. The corresponding problem is solved using Benders decomposition method. The proposed methodology is evaluated using the IEEE 300-bus test system.\",\"PeriodicalId\":445295,\"journal\":{\"name\":\"2013 13th International Conference on Environment and Electrical Engineering (EEEIC)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 13th International Conference on Environment and Electrical Engineering (EEEIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EEEIC-2.2013.6737876\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 13th International Conference on Environment and Electrical Engineering (EEEIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEEIC-2.2013.6737876","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Transmission system reconfiguration for congestion management ensuring transient and voltage stability
Transmission congestion management has been an important issue to power system operators and planners. As of the remedial/preventive actions, transmission reconfiguration has been employed to relieve congestion. In this paper, a methodology is proposed which optimally determines the system configuration to relieve congestion while respecting system security limits such as N-1 contingency criteria, voltage limits, voltage stability margin and transient stability. Most of these important criteria have been overlooked in the previous literature. The corresponding problem is solved using Benders decomposition method. The proposed methodology is evaluated using the IEEE 300-bus test system.