{"title":"绝缘体/电解质界面表面电位和ζ电位的组合测量","authors":"L. Bousse, S. Mostarshed, D. Hafeman","doi":"10.1109/SENSOR.1991.148922","DOIUrl":null,"url":null,"abstract":"Simultaneous measurements of relative surface potential and zeta potential, as monitored by streaming potential measurement, were made at the interface between Si/sub 3/N/sub 4/ (on a semiconductor substrate) and aqueous electrolytes of varied pH. The light-addressable-potentiometric-sensor (LAPS) technique was used to make the simultaneous measurements. The results indicate the zero zeta potential occurred at an electrolyte pH of 3.1. Upon changing pH, approximately 10% of the surface potential change also appeared as a change in zeta potential.<<ETX>>","PeriodicalId":273871,"journal":{"name":"TRANSDUCERS '91: 1991 International Conference on Solid-State Sensors and Actuators. Digest of Technical Papers","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Combined measurement of surface potential and zeta potential at insulator/electrolyte interfaces\",\"authors\":\"L. Bousse, S. Mostarshed, D. Hafeman\",\"doi\":\"10.1109/SENSOR.1991.148922\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Simultaneous measurements of relative surface potential and zeta potential, as monitored by streaming potential measurement, were made at the interface between Si/sub 3/N/sub 4/ (on a semiconductor substrate) and aqueous electrolytes of varied pH. The light-addressable-potentiometric-sensor (LAPS) technique was used to make the simultaneous measurements. The results indicate the zero zeta potential occurred at an electrolyte pH of 3.1. Upon changing pH, approximately 10% of the surface potential change also appeared as a change in zeta potential.<<ETX>>\",\"PeriodicalId\":273871,\"journal\":{\"name\":\"TRANSDUCERS '91: 1991 International Conference on Solid-State Sensors and Actuators. Digest of Technical Papers\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TRANSDUCERS '91: 1991 International Conference on Solid-State Sensors and Actuators. Digest of Technical Papers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SENSOR.1991.148922\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TRANSDUCERS '91: 1991 International Conference on Solid-State Sensors and Actuators. Digest of Technical Papers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.1991.148922","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Combined measurement of surface potential and zeta potential at insulator/electrolyte interfaces
Simultaneous measurements of relative surface potential and zeta potential, as monitored by streaming potential measurement, were made at the interface between Si/sub 3/N/sub 4/ (on a semiconductor substrate) and aqueous electrolytes of varied pH. The light-addressable-potentiometric-sensor (LAPS) technique was used to make the simultaneous measurements. The results indicate the zero zeta potential occurred at an electrolyte pH of 3.1. Upon changing pH, approximately 10% of the surface potential change also appeared as a change in zeta potential.<>