50GHz以下tsv的双t型等效电路建模方法

Xiangkun Yin, Zhangming Zhu, Yintang Yang, Qijun Lu, Xiaoxian Liu, Yang Liu
{"title":"50GHz以下tsv的双t型等效电路建模方法","authors":"Xiangkun Yin, Zhangming Zhu, Yintang Yang, Qijun Lu, Xiaoxian Liu, Yang Liu","doi":"10.1109/EDAPS.2017.8277026","DOIUrl":null,"url":null,"abstract":"The three-dimensional integrated circuits (3D ICs) based on through silicon via (TSV) technology offer a solution to meet the continuously increasing demand on high-speed electronic products. In order to comprehensively evaluate the signal transmission of TSV in increasing signal frequency, accuracy equivalent circuit model is necessary. In this paper, a method of double-T type equivalent circuit modelling for TSVs is proposed and applied to coaxial TSV and ground-signal (GS)-type TSVs. Furthermore, the transmission parameters (S21) of the double-T models are evaluated by SPICE and compared with the results of 3-D full-wave electromagnetic field simulation (HFSS). The good accordance of the results up to 50GHz verifies the accuracy of the proposed method.","PeriodicalId":329279,"journal":{"name":"2017 IEEE Electrical Design of Advanced Packaging and Systems Symposium (EDAPS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Double-T type equivalent circuit modelling method for TSVs up to 50GHz\",\"authors\":\"Xiangkun Yin, Zhangming Zhu, Yintang Yang, Qijun Lu, Xiaoxian Liu, Yang Liu\",\"doi\":\"10.1109/EDAPS.2017.8277026\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The three-dimensional integrated circuits (3D ICs) based on through silicon via (TSV) technology offer a solution to meet the continuously increasing demand on high-speed electronic products. In order to comprehensively evaluate the signal transmission of TSV in increasing signal frequency, accuracy equivalent circuit model is necessary. In this paper, a method of double-T type equivalent circuit modelling for TSVs is proposed and applied to coaxial TSV and ground-signal (GS)-type TSVs. Furthermore, the transmission parameters (S21) of the double-T models are evaluated by SPICE and compared with the results of 3-D full-wave electromagnetic field simulation (HFSS). The good accordance of the results up to 50GHz verifies the accuracy of the proposed method.\",\"PeriodicalId\":329279,\"journal\":{\"name\":\"2017 IEEE Electrical Design of Advanced Packaging and Systems Symposium (EDAPS)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE Electrical Design of Advanced Packaging and Systems Symposium (EDAPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EDAPS.2017.8277026\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Electrical Design of Advanced Packaging and Systems Symposium (EDAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDAPS.2017.8277026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

基于硅通孔(TSV)技术的三维集成电路(3D ic)为满足高速电子产品不断增长的需求提供了解决方案。为了全面评价TSV在增加信号频率时的信号传输情况,需要建立精度等效电路模型。本文提出了一种TSV双t型等效电路建模方法,并将其应用于同轴TSV和地信号(GS)型TSV。利用SPICE计算了双t模型的传输参数S21,并与三维全波电磁场仿真(HFSS)结果进行了比较。在50GHz范围内的结果吻合良好,验证了所提方法的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Double-T type equivalent circuit modelling method for TSVs up to 50GHz
The three-dimensional integrated circuits (3D ICs) based on through silicon via (TSV) technology offer a solution to meet the continuously increasing demand on high-speed electronic products. In order to comprehensively evaluate the signal transmission of TSV in increasing signal frequency, accuracy equivalent circuit model is necessary. In this paper, a method of double-T type equivalent circuit modelling for TSVs is proposed and applied to coaxial TSV and ground-signal (GS)-type TSVs. Furthermore, the transmission parameters (S21) of the double-T models are evaluated by SPICE and compared with the results of 3-D full-wave electromagnetic field simulation (HFSS). The good accordance of the results up to 50GHz verifies the accuracy of the proposed method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信