{"title":"单相并网逆变系统的控制","authors":"J. Šedo, S. Kaščák","doi":"10.1109/ELEKTRO.2016.7512066","DOIUrl":null,"url":null,"abstract":"In this paper, an implementation of the control and the synchronization algorithms for a Voltage Source Inverter used in a grid-connected structure is carried out. The main purpose is to show the combined operation of the control and synchronization algorithm for achieving the proper behavior of the grid inverter for the single phase utility grid system. In order to obtain a proper functionality of the system during perturbation, a proportional integral controller structure along with Second Order Generalized Integrator Phase-Locked Loop (SOGI PLL) is designed and used as synchronization algorithm. Also, the aim is to control power factor at grid, to feed power into the grid, and to decrease phase current distortion of VSI. Secondly, the design of third order LCL output filter will be proposed in this paper. The results of simulations of the inverter system connected to grid (220V, 50 Hz) using MATLAB/Simulink are also shown. Simulation results confirms that the grid input power factor is nearly unity, and the distortion of phase current of the proposed system is reduced, causing the total harmonic distortion for various power conditions falls within 5%.","PeriodicalId":369251,"journal":{"name":"2016 ELEKTRO","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Control of single-phase grid connected inverter system\",\"authors\":\"J. Šedo, S. Kaščák\",\"doi\":\"10.1109/ELEKTRO.2016.7512066\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, an implementation of the control and the synchronization algorithms for a Voltage Source Inverter used in a grid-connected structure is carried out. The main purpose is to show the combined operation of the control and synchronization algorithm for achieving the proper behavior of the grid inverter for the single phase utility grid system. In order to obtain a proper functionality of the system during perturbation, a proportional integral controller structure along with Second Order Generalized Integrator Phase-Locked Loop (SOGI PLL) is designed and used as synchronization algorithm. Also, the aim is to control power factor at grid, to feed power into the grid, and to decrease phase current distortion of VSI. Secondly, the design of third order LCL output filter will be proposed in this paper. The results of simulations of the inverter system connected to grid (220V, 50 Hz) using MATLAB/Simulink are also shown. Simulation results confirms that the grid input power factor is nearly unity, and the distortion of phase current of the proposed system is reduced, causing the total harmonic distortion for various power conditions falls within 5%.\",\"PeriodicalId\":369251,\"journal\":{\"name\":\"2016 ELEKTRO\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 ELEKTRO\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELEKTRO.2016.7512066\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 ELEKTRO","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELEKTRO.2016.7512066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

本文给出了一种用于并网结构的电压源逆变器的控制和同步算法的实现。主要目的是展示控制和同步算法的联合运行,以实现单相公用电网系统的并网逆变器的正常行为。为了使系统在摄动时具有适当的功能,设计了一种比例积分控制器结构,并结合二阶广义积分器锁相环(SOGI PLL)作为同步算法。同时,控制电网的功率因数,向电网供电,降低VSI的相电流畸变。其次,本文提出了三阶LCL输出滤波器的设计。最后给出了利用MATLAB/Simulink对逆变系统并网(220V, 50 Hz)的仿真结果。仿真结果表明,电网输入功率因数基本一致,减小了系统相电流畸变,各种功率条件下的总谐波畸变在5%以内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Control of single-phase grid connected inverter system
In this paper, an implementation of the control and the synchronization algorithms for a Voltage Source Inverter used in a grid-connected structure is carried out. The main purpose is to show the combined operation of the control and synchronization algorithm for achieving the proper behavior of the grid inverter for the single phase utility grid system. In order to obtain a proper functionality of the system during perturbation, a proportional integral controller structure along with Second Order Generalized Integrator Phase-Locked Loop (SOGI PLL) is designed and used as synchronization algorithm. Also, the aim is to control power factor at grid, to feed power into the grid, and to decrease phase current distortion of VSI. Secondly, the design of third order LCL output filter will be proposed in this paper. The results of simulations of the inverter system connected to grid (220V, 50 Hz) using MATLAB/Simulink are also shown. Simulation results confirms that the grid input power factor is nearly unity, and the distortion of phase current of the proposed system is reduced, causing the total harmonic distortion for various power conditions falls within 5%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信