A. P. Leão, M. Tostes, J. P. A. Vieira, U. Bezerra, W. Heringer, A. L. Sousa, M. D. A. Cordeiro, J. C. H. Paye, M. C. Santos
{"title":"竹枝架空配电网高阻抗故障特性研究","authors":"A. P. Leão, M. Tostes, J. P. A. Vieira, U. Bezerra, W. Heringer, A. L. Sousa, M. D. A. Cordeiro, J. C. H. Paye, M. C. Santos","doi":"10.1109/TDLA47668.2020.9326100","DOIUrl":null,"url":null,"abstract":"The high impedance fault (HIF) has as one of its main characteristics the low magnitude of the current produced, causing its detection and location to be impaired for the equipment currently used to protect electrical power systems, which favors the driver remain energized, increasing the likelihood of fires and the risk of death for living beings. Records of HIF characteristics in trees are a gap in the literature, making it difficult to develop new algorithms and identification methods. This study presents details of the voltage and current characteristics of HIF in bamboo tree branches, the result of experimental tests carried out in a laboratory designed and assembled for HIF simulation in overhead distribution networks, and the capture of these oscillography was carried out by a relay commercial protection.","PeriodicalId":448644,"journal":{"name":"2020 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D LA)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Characteristics of High Impedance Faults in Overhead Distribution Networks in Bamboo Branches\",\"authors\":\"A. P. Leão, M. Tostes, J. P. A. Vieira, U. Bezerra, W. Heringer, A. L. Sousa, M. D. A. Cordeiro, J. C. H. Paye, M. C. Santos\",\"doi\":\"10.1109/TDLA47668.2020.9326100\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The high impedance fault (HIF) has as one of its main characteristics the low magnitude of the current produced, causing its detection and location to be impaired for the equipment currently used to protect electrical power systems, which favors the driver remain energized, increasing the likelihood of fires and the risk of death for living beings. Records of HIF characteristics in trees are a gap in the literature, making it difficult to develop new algorithms and identification methods. This study presents details of the voltage and current characteristics of HIF in bamboo tree branches, the result of experimental tests carried out in a laboratory designed and assembled for HIF simulation in overhead distribution networks, and the capture of these oscillography was carried out by a relay commercial protection.\",\"PeriodicalId\":448644,\"journal\":{\"name\":\"2020 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D LA)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D LA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TDLA47668.2020.9326100\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D LA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDLA47668.2020.9326100","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Characteristics of High Impedance Faults in Overhead Distribution Networks in Bamboo Branches
The high impedance fault (HIF) has as one of its main characteristics the low magnitude of the current produced, causing its detection and location to be impaired for the equipment currently used to protect electrical power systems, which favors the driver remain energized, increasing the likelihood of fires and the risk of death for living beings. Records of HIF characteristics in trees are a gap in the literature, making it difficult to develop new algorithms and identification methods. This study presents details of the voltage and current characteristics of HIF in bamboo tree branches, the result of experimental tests carried out in a laboratory designed and assembled for HIF simulation in overhead distribution networks, and the capture of these oscillography was carried out by a relay commercial protection.