{"title":"工艺设备组成对电压跌落造成的经济损失的影响","authors":"C. P. Gupta, J. Milanović, M. T. Aung","doi":"10.1109/ICHQP.2004.1409324","DOIUrl":null,"url":null,"abstract":"Power quality (PQ) disturbances can have significant economic consequences for different type of customer faculties. Voltage sags are the most common power quality disturbances causing disruption of consumer equipment. The paper therefore, focuses on voltage sags and discusses economic assessment of power quality. By combining the probabilistic assessment of voltage sags with the voltage tolerance curves of electrical equipment an estimate can be made of the sag events responsible for tripping of the equipment over a specified period of time. If the tripping costs per event of the equipment are available, the assessment of customer financial losses due to the inadequate quality of supply can be made. The effect of sensitive load composition, i.e., type of the industrial process on the customer financial losses (damage costs) due to expected voltage sags at a bus has been investigated in the paper. This approach can be used as a tool to select the most favorable location in the network to connect an industrial plant having particular composition of sensitive equipment.","PeriodicalId":406398,"journal":{"name":"2004 11th International Conference on Harmonics and Quality of Power (IEEE Cat. No.04EX951)","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":"{\"title\":\"The influence of process equipment composition on financial losses due to voltage sags\",\"authors\":\"C. P. Gupta, J. Milanović, M. T. Aung\",\"doi\":\"10.1109/ICHQP.2004.1409324\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power quality (PQ) disturbances can have significant economic consequences for different type of customer faculties. Voltage sags are the most common power quality disturbances causing disruption of consumer equipment. The paper therefore, focuses on voltage sags and discusses economic assessment of power quality. By combining the probabilistic assessment of voltage sags with the voltage tolerance curves of electrical equipment an estimate can be made of the sag events responsible for tripping of the equipment over a specified period of time. If the tripping costs per event of the equipment are available, the assessment of customer financial losses due to the inadequate quality of supply can be made. The effect of sensitive load composition, i.e., type of the industrial process on the customer financial losses (damage costs) due to expected voltage sags at a bus has been investigated in the paper. This approach can be used as a tool to select the most favorable location in the network to connect an industrial plant having particular composition of sensitive equipment.\",\"PeriodicalId\":406398,\"journal\":{\"name\":\"2004 11th International Conference on Harmonics and Quality of Power (IEEE Cat. No.04EX951)\",\"volume\":\"62 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2004 11th International Conference on Harmonics and Quality of Power (IEEE Cat. No.04EX951)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP.2004.1409324\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2004 11th International Conference on Harmonics and Quality of Power (IEEE Cat. No.04EX951)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2004.1409324","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The influence of process equipment composition on financial losses due to voltage sags
Power quality (PQ) disturbances can have significant economic consequences for different type of customer faculties. Voltage sags are the most common power quality disturbances causing disruption of consumer equipment. The paper therefore, focuses on voltage sags and discusses economic assessment of power quality. By combining the probabilistic assessment of voltage sags with the voltage tolerance curves of electrical equipment an estimate can be made of the sag events responsible for tripping of the equipment over a specified period of time. If the tripping costs per event of the equipment are available, the assessment of customer financial losses due to the inadequate quality of supply can be made. The effect of sensitive load composition, i.e., type of the industrial process on the customer financial losses (damage costs) due to expected voltage sags at a bus has been investigated in the paper. This approach can be used as a tool to select the most favorable location in the network to connect an industrial plant having particular composition of sensitive equipment.