从混响室测量和SAR测量中获得的发射结果转换的实验评估

N. van Dijk, K. Banerjee
{"title":"从混响室测量和SAR测量中获得的发射结果转换的实验评估","authors":"N. van Dijk, K. Banerjee","doi":"10.1109/EMCEUROPE.2008.4786919","DOIUrl":null,"url":null,"abstract":"The reverberation chamber (RC) method has many advantages above the semi anechoic room (SAR) method. The RC method is specifically useful to measure emissions at high frequencies (>1 GHz). This is an important property when we consider the trend of increasing operating frequencies of products and wireless applications. Furthermore, the RC method is useful for immunity tests, where we only need moderate power for generating suitable test levels. However, when different methods are used, the topic of conversion arises. In this paper, we specifically consider practical evaluation of the conversion factor of emission results of a CISPR 22 system-test EUT configuration. In addition, we investigate the practical conversion factor of an artificial EUT. From these evaluations, it could be concluded that the RC method is suitable for performing compliance emission measurements and that a conversion factor of around 4 dB is applicable.","PeriodicalId":133902,"journal":{"name":"2008 International Symposium on Electromagnetic Compatibility - EMC Europe","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Experimental evaluation of the conversion of emission results obtained from a Reverberation Chamber measurement and a SAR measurement\",\"authors\":\"N. van Dijk, K. Banerjee\",\"doi\":\"10.1109/EMCEUROPE.2008.4786919\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The reverberation chamber (RC) method has many advantages above the semi anechoic room (SAR) method. The RC method is specifically useful to measure emissions at high frequencies (>1 GHz). This is an important property when we consider the trend of increasing operating frequencies of products and wireless applications. Furthermore, the RC method is useful for immunity tests, where we only need moderate power for generating suitable test levels. However, when different methods are used, the topic of conversion arises. In this paper, we specifically consider practical evaluation of the conversion factor of emission results of a CISPR 22 system-test EUT configuration. In addition, we investigate the practical conversion factor of an artificial EUT. From these evaluations, it could be concluded that the RC method is suitable for performing compliance emission measurements and that a conversion factor of around 4 dB is applicable.\",\"PeriodicalId\":133902,\"journal\":{\"name\":\"2008 International Symposium on Electromagnetic Compatibility - EMC Europe\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 International Symposium on Electromagnetic Compatibility - EMC Europe\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMCEUROPE.2008.4786919\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 International Symposium on Electromagnetic Compatibility - EMC Europe","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCEUROPE.2008.4786919","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

混响室(RC)法比半消声室(SAR)法具有许多优点。RC方法特别适用于测量高频(> 1ghz)的辐射。当我们考虑产品和无线应用的工作频率增加的趋势时,这是一个重要的特性。此外,RC方法对抗扰度测试很有用,我们只需要适度的功率来产生合适的测试水平。然而,当使用不同的方法时,就会出现转换的话题。在本文中,我们特别考虑了CISPR 22系统测试EUT配置的发射结果转换因子的实际评估。此外,我们还研究了人工EUT的实际转换因子。从这些评价中,可以得出结论,RC方法适用于执行合规排放测量,并且转换因子约为4 dB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental evaluation of the conversion of emission results obtained from a Reverberation Chamber measurement and a SAR measurement
The reverberation chamber (RC) method has many advantages above the semi anechoic room (SAR) method. The RC method is specifically useful to measure emissions at high frequencies (>1 GHz). This is an important property when we consider the trend of increasing operating frequencies of products and wireless applications. Furthermore, the RC method is useful for immunity tests, where we only need moderate power for generating suitable test levels. However, when different methods are used, the topic of conversion arises. In this paper, we specifically consider practical evaluation of the conversion factor of emission results of a CISPR 22 system-test EUT configuration. In addition, we investigate the practical conversion factor of an artificial EUT. From these evaluations, it could be concluded that the RC method is suitable for performing compliance emission measurements and that a conversion factor of around 4 dB is applicable.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信