{"title":"三相电力系统不平衡模式最小化方法","authors":"N. Korovkin, Q. S. Vu, R. A. Yazenin","doi":"10.1109/EICONRUSNW.2016.7448257","DOIUrl":null,"url":null,"abstract":"In distributed power system, the unbalanced operating mode, high harmonics, negative sequence components and variation of true power components in the neutral wire, which are caused by the nonlinear or unbalanced loads. It can introduce additional power transmission losses. There are many researches show that various methods for solving this issue, however most of them use compensating devices on all three-phase of bus. This paper presents a new method for minimization of unbalanced operating mode and optimal location of reactive power compensating devices in three-phase power systems, without attention to the mode of each separate phase. The method focuses on reducing the number of reactive power compensating devices at each distributed bus.","PeriodicalId":262452,"journal":{"name":"2016 IEEE NW Russia Young Researchers in Electrical and Electronic Engineering Conference (EIConRusNW)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"A method for minimization of unbalanced mode in three-phase power systems\",\"authors\":\"N. Korovkin, Q. S. Vu, R. A. Yazenin\",\"doi\":\"10.1109/EICONRUSNW.2016.7448257\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In distributed power system, the unbalanced operating mode, high harmonics, negative sequence components and variation of true power components in the neutral wire, which are caused by the nonlinear or unbalanced loads. It can introduce additional power transmission losses. There are many researches show that various methods for solving this issue, however most of them use compensating devices on all three-phase of bus. This paper presents a new method for minimization of unbalanced operating mode and optimal location of reactive power compensating devices in three-phase power systems, without attention to the mode of each separate phase. The method focuses on reducing the number of reactive power compensating devices at each distributed bus.\",\"PeriodicalId\":262452,\"journal\":{\"name\":\"2016 IEEE NW Russia Young Researchers in Electrical and Electronic Engineering Conference (EIConRusNW)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE NW Russia Young Researchers in Electrical and Electronic Engineering Conference (EIConRusNW)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EICONRUSNW.2016.7448257\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE NW Russia Young Researchers in Electrical and Electronic Engineering Conference (EIConRusNW)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EICONRUSNW.2016.7448257","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

在分布式电力系统中,由非线性或不平衡负载引起的不平衡运行方式、高次谐波、负序分量和中性线真功率分量的变化。它可以引入额外的电力传输损失。有许多研究表明,解决这一问题的方法多种多样,但大多数都是在母线的所有三相上使用补偿装置。本文提出了一种新的方法,在不考虑各相模式的情况下,使三相电力系统的不平衡运行模式最小化和无功补偿装置的最优位置。该方法的重点是减少每个分布式母线上无功补偿装置的数量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A method for minimization of unbalanced mode in three-phase power systems
In distributed power system, the unbalanced operating mode, high harmonics, negative sequence components and variation of true power components in the neutral wire, which are caused by the nonlinear or unbalanced loads. It can introduce additional power transmission losses. There are many researches show that various methods for solving this issue, however most of them use compensating devices on all three-phase of bus. This paper presents a new method for minimization of unbalanced operating mode and optimal location of reactive power compensating devices in three-phase power systems, without attention to the mode of each separate phase. The method focuses on reducing the number of reactive power compensating devices at each distributed bus.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信