考虑电流误差限制的永磁同步电机模型预测控制共模电压抑制方法

Xiaofan Wang, Xiaochun Fang, F. Lin, Zhongping Yang
{"title":"考虑电流误差限制的永磁同步电机模型预测控制共模电压抑制方法","authors":"Xiaofan Wang, Xiaochun Fang, F. Lin, Zhongping Yang","doi":"10.2495/CR180101","DOIUrl":null,"url":null,"abstract":"The common mode voltage (CMV) generated by the inverter will lead to bearing damage and electromagnetic interference issues. This paper studies the CMV suppression method based on finite control set model predictive control (FCS-MPC) for permanent magnet synchronous motor (PMSM) drive fed by voltage source inverter. The advantage of the method proposed in this paper is that it balances both current quality assurance and CMV suppression. The balance of the current quality and CMV suppression can be achieved by adjusting a single parameter. Meanwhile, the method can maintain low switching frequency. The performance of the proposed method was evaluated by computer simulation and compared with other methods.","PeriodicalId":210834,"journal":{"name":"Computers in Railways XVI : Railway Engineering Design and Operation","volume":"69 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"COMMON MODE VOLTAGE SUPPRESSION METHOD BASED ON MODEL PREDICTIVE CONTROL FOR A PERMANENT MAGNET SYNCHRONOUS MOTOR CONSIDERING CURRENT ERROR LIMIT\",\"authors\":\"Xiaofan Wang, Xiaochun Fang, F. Lin, Zhongping Yang\",\"doi\":\"10.2495/CR180101\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The common mode voltage (CMV) generated by the inverter will lead to bearing damage and electromagnetic interference issues. This paper studies the CMV suppression method based on finite control set model predictive control (FCS-MPC) for permanent magnet synchronous motor (PMSM) drive fed by voltage source inverter. The advantage of the method proposed in this paper is that it balances both current quality assurance and CMV suppression. The balance of the current quality and CMV suppression can be achieved by adjusting a single parameter. Meanwhile, the method can maintain low switching frequency. The performance of the proposed method was evaluated by computer simulation and compared with other methods.\",\"PeriodicalId\":210834,\"journal\":{\"name\":\"Computers in Railways XVI : Railway Engineering Design and Operation\",\"volume\":\"69 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computers in Railways XVI : Railway Engineering Design and Operation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2495/CR180101\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers in Railways XVI : Railway Engineering Design and Operation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2495/CR180101","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

逆变器产生的共模电压(CMV)会导致轴承损坏和电磁干扰问题。研究了基于有限控制集模型预测控制(FCS-MPC)的电压源逆变器驱动永磁同步电机CMV抑制方法。本文提出的方法的优点是它平衡了当前质量保证和CMV抑制。通过调整单个参数可以实现电流质量和CMV抑制的平衡。同时,该方法可以保持较低的开关频率。通过计算机仿真对该方法的性能进行了评价,并与其他方法进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
COMMON MODE VOLTAGE SUPPRESSION METHOD BASED ON MODEL PREDICTIVE CONTROL FOR A PERMANENT MAGNET SYNCHRONOUS MOTOR CONSIDERING CURRENT ERROR LIMIT
The common mode voltage (CMV) generated by the inverter will lead to bearing damage and electromagnetic interference issues. This paper studies the CMV suppression method based on finite control set model predictive control (FCS-MPC) for permanent magnet synchronous motor (PMSM) drive fed by voltage source inverter. The advantage of the method proposed in this paper is that it balances both current quality assurance and CMV suppression. The balance of the current quality and CMV suppression can be achieved by adjusting a single parameter. Meanwhile, the method can maintain low switching frequency. The performance of the proposed method was evaluated by computer simulation and compared with other methods.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信