{"title":"类似焊接接头事后组织与力学性能分析","authors":"A. Merda, Klaudia Klimaszewska","doi":"10.17729/EBIS.2020.6/3","DOIUrl":null,"url":null,"abstract":"The test material was a specimen sampled from sections of a pipe operated for 41,914 hours at a temperature of 575°C and under a steam pressure of 28.2 MPa. The specimen subjected to metallurgical tests was a welded joint made of austenitic steel TP347HFG. The non-destructive tests and the macroscopic tests confirmed the lack of any welding imperfections. The test joint represented quality level B in accordance with related standard requirements. The microstructural tests of the heat-affected zone (HAZ) revealed the presence of the fine-grained austenitic structure with numerous precipitates on grain boundaries – probably M23C6 carbides. In spite of long-lasting operation, the mechanical properties of the test welded joint were high and did not exceed the standard-related requirements concerning the base material.","PeriodicalId":184101,"journal":{"name":"Biuletyn Instytutu Spawalnictwa","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Analysis of the Post-Operation Microstructure and Mechanical Properties of the Similar Welded Joint\",\"authors\":\"A. Merda, Klaudia Klimaszewska\",\"doi\":\"10.17729/EBIS.2020.6/3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The test material was a specimen sampled from sections of a pipe operated for 41,914 hours at a temperature of 575°C and under a steam pressure of 28.2 MPa. The specimen subjected to metallurgical tests was a welded joint made of austenitic steel TP347HFG. The non-destructive tests and the macroscopic tests confirmed the lack of any welding imperfections. The test joint represented quality level B in accordance with related standard requirements. The microstructural tests of the heat-affected zone (HAZ) revealed the presence of the fine-grained austenitic structure with numerous precipitates on grain boundaries – probably M23C6 carbides. In spite of long-lasting operation, the mechanical properties of the test welded joint were high and did not exceed the standard-related requirements concerning the base material.\",\"PeriodicalId\":184101,\"journal\":{\"name\":\"Biuletyn Instytutu Spawalnictwa\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biuletyn Instytutu Spawalnictwa\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17729/EBIS.2020.6/3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biuletyn Instytutu Spawalnictwa","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17729/EBIS.2020.6/3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Analysis of the Post-Operation Microstructure and Mechanical Properties of the Similar Welded Joint
The test material was a specimen sampled from sections of a pipe operated for 41,914 hours at a temperature of 575°C and under a steam pressure of 28.2 MPa. The specimen subjected to metallurgical tests was a welded joint made of austenitic steel TP347HFG. The non-destructive tests and the macroscopic tests confirmed the lack of any welding imperfections. The test joint represented quality level B in accordance with related standard requirements. The microstructural tests of the heat-affected zone (HAZ) revealed the presence of the fine-grained austenitic structure with numerous precipitates on grain boundaries – probably M23C6 carbides. In spite of long-lasting operation, the mechanical properties of the test welded joint were high and did not exceed the standard-related requirements concerning the base material.