基于DVR的太阳能光伏馈电阻抗源逆变器电压膨胀最小化

M. Prasad, J. MunichandraSekhar, A. K. Akella
{"title":"基于DVR的太阳能光伏馈电阻抗源逆变器电压膨胀最小化","authors":"M. Prasad, J. MunichandraSekhar, A. K. Akella","doi":"10.1109/ICCTCT.2018.8550844","DOIUrl":null,"url":null,"abstract":"Impedance or Z-Source inverter is an emerging power converter topology that has been used as a step-up and step-down converter in a single unit. This paper presents a solar photovoltaic fed impedance or Z-source inverter (ZSI) based Dynamic Voltage Restorer (DVR) for the alleviation of destructive voltage swells in a power distribution system. This article also proposed a hybrid technique for optimum maximum power point tracking (MPPT). The proposed hybrid technique is the combination of the perturbation and observation (P&O) technique and the incremental conductance (InC) technique. The design, modeling and simulation of the proposed PV-ZSI-DVR are implemented in MATLAB/SIMULINK for mitigation of voltage swell and the obtained results are compared with traditional SPV fed voltage source inverter (VSI) and current source inverter (CSI) based DVRs.","PeriodicalId":344188,"journal":{"name":"2018 International Conference on Current Trends towards Converging Technologies (ICCTCT)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Voltage Swell Minimization by Solar Photovoltaic Fed Impedance-Source Inverter Based DVR\",\"authors\":\"M. Prasad, J. MunichandraSekhar, A. K. Akella\",\"doi\":\"10.1109/ICCTCT.2018.8550844\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Impedance or Z-Source inverter is an emerging power converter topology that has been used as a step-up and step-down converter in a single unit. This paper presents a solar photovoltaic fed impedance or Z-source inverter (ZSI) based Dynamic Voltage Restorer (DVR) for the alleviation of destructive voltage swells in a power distribution system. This article also proposed a hybrid technique for optimum maximum power point tracking (MPPT). The proposed hybrid technique is the combination of the perturbation and observation (P&O) technique and the incremental conductance (InC) technique. The design, modeling and simulation of the proposed PV-ZSI-DVR are implemented in MATLAB/SIMULINK for mitigation of voltage swell and the obtained results are compared with traditional SPV fed voltage source inverter (VSI) and current source inverter (CSI) based DVRs.\",\"PeriodicalId\":344188,\"journal\":{\"name\":\"2018 International Conference on Current Trends towards Converging Technologies (ICCTCT)\",\"volume\":\"30 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Conference on Current Trends towards Converging Technologies (ICCTCT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCTCT.2018.8550844\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Current Trends towards Converging Technologies (ICCTCT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCTCT.2018.8550844","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

阻抗或z源逆变器是一种新兴的功率转换器拓扑结构,已被用作单个单元中的升压和降压转换器。本文提出了一种基于太阳能光伏馈电阻抗或z源逆变器(ZSI)的动态电压恢复器(DVR),用于缓解配电系统中的破坏性电压波动。本文还提出了一种用于最优最大功率点跟踪的混合技术。提出的混合技术是微扰观测(P&O)技术和增量电导(InC)技术的结合。在MATLAB/SIMULINK中实现了PV-ZSI-DVR的设计、建模和仿真,并与传统的SPV馈电电压源逆变器(VSI)和基于电流源逆变器(CSI)的dvr进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Voltage Swell Minimization by Solar Photovoltaic Fed Impedance-Source Inverter Based DVR
Impedance or Z-Source inverter is an emerging power converter topology that has been used as a step-up and step-down converter in a single unit. This paper presents a solar photovoltaic fed impedance or Z-source inverter (ZSI) based Dynamic Voltage Restorer (DVR) for the alleviation of destructive voltage swells in a power distribution system. This article also proposed a hybrid technique for optimum maximum power point tracking (MPPT). The proposed hybrid technique is the combination of the perturbation and observation (P&O) technique and the incremental conductance (InC) technique. The design, modeling and simulation of the proposed PV-ZSI-DVR are implemented in MATLAB/SIMULINK for mitigation of voltage swell and the obtained results are compared with traditional SPV fed voltage source inverter (VSI) and current source inverter (CSI) based DVRs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信