用三室药代动力学模型生成医用注射剂安全指南

Cunxi Yu, Heinz Riener, Francesca Stradolini, G. Micheli
{"title":"用三室药代动力学模型生成医用注射剂安全指南","authors":"Cunxi Yu, Heinz Riener, Francesca Stradolini, G. Micheli","doi":"10.1109/ISVLSI.2018.00062","DOIUrl":null,"url":null,"abstract":"Medical cyber-physical systems are a new trend of software controlled physical systems that are increasingly common in medical domains. With rapid developments in medical science and computer technology, safety verification and simulation becomes more challenging. This paper introduces a general model for medical injection systems, which can be used for formal verification, simulation/testing, and computing the Area Under the Curve (AUC) metrics, using Satisfiability Modulo Theories (SMT) over Reals. An algorithm of computing constrained AUC for measuring drug exposure with relative baseline, is presented based on the proof of unsatisfiability. We demonstrate that our model can efficiently solve these problems using the state-of-the-art SMT solver dReal.","PeriodicalId":114330,"journal":{"name":"2018 IEEE Computer Society Annual Symposium on VLSI (ISVLSI)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Generating Safety Guidance for Medical Injection with Three-Compartment Pharmacokinetics Model\",\"authors\":\"Cunxi Yu, Heinz Riener, Francesca Stradolini, G. Micheli\",\"doi\":\"10.1109/ISVLSI.2018.00062\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Medical cyber-physical systems are a new trend of software controlled physical systems that are increasingly common in medical domains. With rapid developments in medical science and computer technology, safety verification and simulation becomes more challenging. This paper introduces a general model for medical injection systems, which can be used for formal verification, simulation/testing, and computing the Area Under the Curve (AUC) metrics, using Satisfiability Modulo Theories (SMT) over Reals. An algorithm of computing constrained AUC for measuring drug exposure with relative baseline, is presented based on the proof of unsatisfiability. We demonstrate that our model can efficiently solve these problems using the state-of-the-art SMT solver dReal.\",\"PeriodicalId\":114330,\"journal\":{\"name\":\"2018 IEEE Computer Society Annual Symposium on VLSI (ISVLSI)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Computer Society Annual Symposium on VLSI (ISVLSI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISVLSI.2018.00062\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Computer Society Annual Symposium on VLSI (ISVLSI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISVLSI.2018.00062","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

医疗信息物理系统是软件控制物理系统的一个新趋势,在医疗领域越来越普遍。随着医学科学和计算机技术的飞速发展,安全验证与仿真变得越来越具有挑战性。本文介绍了一种用于医用注射系统的通用模型,该模型可用于形式验证、仿真/测试和计算曲线下面积(AUC)指标,使用可满足模理论(SMT)在实数上。在不满意性证明的基础上,提出了一种用相对基线计算药物暴露量的约束AUC算法。我们证明了我们的模型可以使用最先进的SMT求解器dReal有效地解决这些问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Generating Safety Guidance for Medical Injection with Three-Compartment Pharmacokinetics Model
Medical cyber-physical systems are a new trend of software controlled physical systems that are increasingly common in medical domains. With rapid developments in medical science and computer technology, safety verification and simulation becomes more challenging. This paper introduces a general model for medical injection systems, which can be used for formal verification, simulation/testing, and computing the Area Under the Curve (AUC) metrics, using Satisfiability Modulo Theories (SMT) over Reals. An algorithm of computing constrained AUC for measuring drug exposure with relative baseline, is presented based on the proof of unsatisfiability. We demonstrate that our model can efficiently solve these problems using the state-of-the-art SMT solver dReal.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信