水轮发电机转子绕组匝间短路故障多回路模型及仿真研究

Li Yong-gang, Shi Wei
{"title":"水轮发电机转子绕组匝间短路故障多回路模型及仿真研究","authors":"Li Yong-gang, Shi Wei","doi":"10.1109/ICEMS.2011.6073346","DOIUrl":null,"url":null,"abstract":"In the power system, 1/3 of the load is by hydro-generating power supply where its reliability is important requirement. Rotor internal turn-to-turn short circuit is a common fault in hydro-generators. It will cause serious damages if such faults are not handled properly in time. For this reason, according to the multi-loop method of AC machines this paper proposes multi-loop mathematical model of hydro-generators with inter-turn short circuits fault of field windings. The simulation for the inter-turn short circuit of rotor winding on a six poles hydro-generator is carried out by multi-loop methods and the currents in stator winding parallel branches of same phase are calculated quantitatively, based on the analysis, the paper gives the value of the fractional harmonic circulation, which will provide the protection basis for the hydro-generators with rotor winding inter-turn short circuit fault.","PeriodicalId":101507,"journal":{"name":"2011 International Conference on Electrical Machines and Systems","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Multi-loop model and simulation research of hydrogenerators with rotor winding inter-turn short circuit fault\",\"authors\":\"Li Yong-gang, Shi Wei\",\"doi\":\"10.1109/ICEMS.2011.6073346\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the power system, 1/3 of the load is by hydro-generating power supply where its reliability is important requirement. Rotor internal turn-to-turn short circuit is a common fault in hydro-generators. It will cause serious damages if such faults are not handled properly in time. For this reason, according to the multi-loop method of AC machines this paper proposes multi-loop mathematical model of hydro-generators with inter-turn short circuits fault of field windings. The simulation for the inter-turn short circuit of rotor winding on a six poles hydro-generator is carried out by multi-loop methods and the currents in stator winding parallel branches of same phase are calculated quantitatively, based on the analysis, the paper gives the value of the fractional harmonic circulation, which will provide the protection basis for the hydro-generators with rotor winding inter-turn short circuit fault.\",\"PeriodicalId\":101507,\"journal\":{\"name\":\"2011 International Conference on Electrical Machines and Systems\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Electrical Machines and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEMS.2011.6073346\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Electrical Machines and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMS.2011.6073346","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

在电力系统中,1/3的负荷由水轮发电供电,对其可靠性提出了重要要求。转子内部匝间短路是水轮发电机的常见故障。如果不及时处理,将会造成严重的损失。为此,根据交流电机的多回路方法,提出了水轮发电机励磁绕组匝间短路故障的多回路数学模型。采用多回路法对某六极水轮发电机转子绕组匝间短路进行了仿真,定量计算了定子绕组同相并联支路电流,在此基础上给出了分次谐波环流值,为水轮发电机转子绕组匝间短路故障提供了保护依据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multi-loop model and simulation research of hydrogenerators with rotor winding inter-turn short circuit fault
In the power system, 1/3 of the load is by hydro-generating power supply where its reliability is important requirement. Rotor internal turn-to-turn short circuit is a common fault in hydro-generators. It will cause serious damages if such faults are not handled properly in time. For this reason, according to the multi-loop method of AC machines this paper proposes multi-loop mathematical model of hydro-generators with inter-turn short circuits fault of field windings. The simulation for the inter-turn short circuit of rotor winding on a six poles hydro-generator is carried out by multi-loop methods and the currents in stator winding parallel branches of same phase are calculated quantitatively, based on the analysis, the paper gives the value of the fractional harmonic circulation, which will provide the protection basis for the hydro-generators with rotor winding inter-turn short circuit fault.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信