{"title":"基于独立分量分析和Chauvenet准则的脑电信号中眼部伪影的自动去除","authors":"Salim Çinar, Nurettin Acır","doi":"10.1109/TIPTEKNO.2016.7863103","DOIUrl":null,"url":null,"abstract":"Eye movements (saccade, blink and etc.) cause artefacts in Electroencephalogram recordings. The ocular artefact can distort the EEG signals. Removal of ocular artefact is important issue in EEG signal analysis. The main task of artefact removal algorithms is to obtain cleaned EEG without losing meaningful EEG signal. The main focus of this work is to remove ocular artefact automatically by using Independent Component Analysis and Chauvenet criterion. The method is tested on real dataset. Relative error and Correlation coefficient are used for the performance test. The performance of the proposed method was Relative error= 0.273±0.148, Correlation coefficients 0.943± 0.042 in the dataset. The results show that the porposed method effectively removes ocular artefacts in EEG.","PeriodicalId":431660,"journal":{"name":"2016 Medical Technologies National Congress (TIPTEKNO)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Automatic removal of ocular artefacts in EEG signal by using independent component analysis and Chauvenet criterion\",\"authors\":\"Salim Çinar, Nurettin Acır\",\"doi\":\"10.1109/TIPTEKNO.2016.7863103\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Eye movements (saccade, blink and etc.) cause artefacts in Electroencephalogram recordings. The ocular artefact can distort the EEG signals. Removal of ocular artefact is important issue in EEG signal analysis. The main task of artefact removal algorithms is to obtain cleaned EEG without losing meaningful EEG signal. The main focus of this work is to remove ocular artefact automatically by using Independent Component Analysis and Chauvenet criterion. The method is tested on real dataset. Relative error and Correlation coefficient are used for the performance test. The performance of the proposed method was Relative error= 0.273±0.148, Correlation coefficients 0.943± 0.042 in the dataset. The results show that the porposed method effectively removes ocular artefacts in EEG.\",\"PeriodicalId\":431660,\"journal\":{\"name\":\"2016 Medical Technologies National Congress (TIPTEKNO)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 Medical Technologies National Congress (TIPTEKNO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TIPTEKNO.2016.7863103\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Medical Technologies National Congress (TIPTEKNO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TIPTEKNO.2016.7863103","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Automatic removal of ocular artefacts in EEG signal by using independent component analysis and Chauvenet criterion
Eye movements (saccade, blink and etc.) cause artefacts in Electroencephalogram recordings. The ocular artefact can distort the EEG signals. Removal of ocular artefact is important issue in EEG signal analysis. The main task of artefact removal algorithms is to obtain cleaned EEG without losing meaningful EEG signal. The main focus of this work is to remove ocular artefact automatically by using Independent Component Analysis and Chauvenet criterion. The method is tested on real dataset. Relative error and Correlation coefficient are used for the performance test. The performance of the proposed method was Relative error= 0.273±0.148, Correlation coefficients 0.943± 0.042 in the dataset. The results show that the porposed method effectively removes ocular artefacts in EEG.