孤岛微电网分布式发电机组频率电压优化控制方案

R. Dhua, S. Goswami, D. Chatterjee
{"title":"孤岛微电网分布式发电机组频率电压优化控制方案","authors":"R. Dhua, S. Goswami, D. Chatterjee","doi":"10.1109/IEMRE52042.2021.9386729","DOIUrl":null,"url":null,"abstract":"Frequency and voltage regulation is an issue of utmost importance when the microgrid is islanded. During islanding, the loads in the system are reallocated to be shared by the distributed generations (DGs) leading to voltage and frequency shifts. These variations should be such that the load does not experience transients. Therefore, an optimization based scheme is proposed for minimizing both frequency and voltage deviations. In the proposed work, the DG unit having largest capacity in the microgrid is assigned as the master controller. This controller calculates the optimized frequency and voltage deviations dynamically at different load levels. Similar procedure is followed by other DG units for setting their respective phase angle and voltage references for individual inverters. Therefore, simultaneous control of frequency and voltage is achieved with proper load sharing among the DG units. Simulations performed in MATLAB/Simulink justify the effectiveness of the proposed controller.","PeriodicalId":202287,"journal":{"name":"2021 Innovations in Energy Management and Renewable Resources(52042)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"An Optimized Frequency and Voltage Control Scheme for Distributed Generation Units of an Islanded Microgrid\",\"authors\":\"R. Dhua, S. Goswami, D. Chatterjee\",\"doi\":\"10.1109/IEMRE52042.2021.9386729\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Frequency and voltage regulation is an issue of utmost importance when the microgrid is islanded. During islanding, the loads in the system are reallocated to be shared by the distributed generations (DGs) leading to voltage and frequency shifts. These variations should be such that the load does not experience transients. Therefore, an optimization based scheme is proposed for minimizing both frequency and voltage deviations. In the proposed work, the DG unit having largest capacity in the microgrid is assigned as the master controller. This controller calculates the optimized frequency and voltage deviations dynamically at different load levels. Similar procedure is followed by other DG units for setting their respective phase angle and voltage references for individual inverters. Therefore, simultaneous control of frequency and voltage is achieved with proper load sharing among the DG units. Simulations performed in MATLAB/Simulink justify the effectiveness of the proposed controller.\",\"PeriodicalId\":202287,\"journal\":{\"name\":\"2021 Innovations in Energy Management and Renewable Resources(52042)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-02-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 Innovations in Energy Management and Renewable Resources(52042)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMRE52042.2021.9386729\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Innovations in Energy Management and Renewable Resources(52042)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMRE52042.2021.9386729","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

当微电网处于孤岛状态时,频率和电压调节是一个至关重要的问题。在孤岛过程中,系统中的负荷被重新分配给分布式发电机组(dg),从而导致电压和频率的偏移。这些变化应使负载不会经历瞬变。因此,提出了一种基于优化的方案,以最小化频率和电压偏差。在本文提出的工作中,将微电网中容量最大的DG机组作为主控制器。该控制器动态计算不同负载水平下的优化频率和电压偏差。其他DG单元也遵循类似的程序,为单个逆变器设置各自的相角和参考电压。因此,通过DG机组之间适当的负载分担,实现了频率和电压的同时控制。在MATLAB/Simulink中进行的仿真验证了所提控制器的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An Optimized Frequency and Voltage Control Scheme for Distributed Generation Units of an Islanded Microgrid
Frequency and voltage regulation is an issue of utmost importance when the microgrid is islanded. During islanding, the loads in the system are reallocated to be shared by the distributed generations (DGs) leading to voltage and frequency shifts. These variations should be such that the load does not experience transients. Therefore, an optimization based scheme is proposed for minimizing both frequency and voltage deviations. In the proposed work, the DG unit having largest capacity in the microgrid is assigned as the master controller. This controller calculates the optimized frequency and voltage deviations dynamically at different load levels. Similar procedure is followed by other DG units for setting their respective phase angle and voltage references for individual inverters. Therefore, simultaneous control of frequency and voltage is achieved with proper load sharing among the DG units. Simulations performed in MATLAB/Simulink justify the effectiveness of the proposed controller.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信