M. F. Koskinas, F. W. Lacerda, I. M. Yamazaki, F. Toledo, M. N. Takeda, M. S. Dias
{"title":"用4πβ-γ软件符合系统对68Ga进行标准化","authors":"M. F. Koskinas, F. W. Lacerda, I. M. Yamazaki, F. Toledo, M. N. Takeda, M. S. Dias","doi":"10.1109/NSSMIC.2012.6551106","DOIUrl":null,"url":null,"abstract":"The present work aims the standardization of 68Ga, a positron emitter of short half-life used in PET (Positron Emission Tomography). The 68Ga standardization was performed in a triple 4πβ-γ coincidence system that consists of a thin window gas-flow proportional counter (PC) in 4π geometry coupled to a NaI(TI) scintillator and a HPGe crystal, for gamma-ray detection. The data acquisition was carried out by means of a Software Coincidence System (SCS) developed at the Nuclear Metrology Laboratory (Laboratorio de Metrologia Nuclear - LMN) at the IPEN-CNEN/SP. The final results were obtained from a multiple curve fitting applying a covariance matrix methodology combining experimental results with those determined by the Monte Carlo simulation.","PeriodicalId":187728,"journal":{"name":"2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Standardization of 68Ga by means of a 4πβ-γ Software Coincidence System\",\"authors\":\"M. F. Koskinas, F. W. Lacerda, I. M. Yamazaki, F. Toledo, M. N. Takeda, M. S. Dias\",\"doi\":\"10.1109/NSSMIC.2012.6551106\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The present work aims the standardization of 68Ga, a positron emitter of short half-life used in PET (Positron Emission Tomography). The 68Ga standardization was performed in a triple 4πβ-γ coincidence system that consists of a thin window gas-flow proportional counter (PC) in 4π geometry coupled to a NaI(TI) scintillator and a HPGe crystal, for gamma-ray detection. The data acquisition was carried out by means of a Software Coincidence System (SCS) developed at the Nuclear Metrology Laboratory (Laboratorio de Metrologia Nuclear - LMN) at the IPEN-CNEN/SP. The final results were obtained from a multiple curve fitting applying a covariance matrix methodology combining experimental results with those determined by the Monte Carlo simulation.\",\"PeriodicalId\":187728,\"journal\":{\"name\":\"2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2012.6551106\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2012.6551106","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
68Ga是一种短半衰期正电子发射体,用于PET(正电子发射断层扫描)的标准化研究。68Ga标准化在一个4π三重β-γ符合系统中进行,该系统由一个4π几何形状的薄窗气体流动比例计数器(PC)与一个NaI(TI)闪烁体和一个HPGe晶体耦合组成,用于伽马射线检测。数据采集由IPEN-CNEN/SP的核计量实验室(Laboratory de Metrologia Nuclear - LMN)开发的软件重合系统(SCS)进行。将实验结果与蒙特卡罗模拟结果相结合,采用协方差矩阵法进行多次曲线拟合,得到最终结果。
Standardization of 68Ga by means of a 4πβ-γ Software Coincidence System
The present work aims the standardization of 68Ga, a positron emitter of short half-life used in PET (Positron Emission Tomography). The 68Ga standardization was performed in a triple 4πβ-γ coincidence system that consists of a thin window gas-flow proportional counter (PC) in 4π geometry coupled to a NaI(TI) scintillator and a HPGe crystal, for gamma-ray detection. The data acquisition was carried out by means of a Software Coincidence System (SCS) developed at the Nuclear Metrology Laboratory (Laboratorio de Metrologia Nuclear - LMN) at the IPEN-CNEN/SP. The final results were obtained from a multiple curve fitting applying a covariance matrix methodology combining experimental results with those determined by the Monte Carlo simulation.