超高压线路的相位设计及导线截面调整

M. Bělík, Lykhovyd Yuri, V. Kuchanskyy, O. Rubanenko
{"title":"超高压线路的相位设计及导线截面调整","authors":"M. Bělík, Lykhovyd Yuri, V. Kuchanskyy, O. Rubanenko","doi":"10.1109/ESS57819.2022.9969287","DOIUrl":null,"url":null,"abstract":"The paper presents the results of the analysis of the economic curves of overhead power lines with subsequent justification of the design of the power line. In the paper, economic curves are constructed for a line with a rated voltage of 750 kV. The cross-sections, the use of which is justified depending on the transmitted power, are determined. The analysis of the influence of design parameters on the occurrence of resonant overvoltages in non-sinusoidal overvoltages has been carried out. Three-dimensional graphs of dependences of overvoltage values on changes in the distance between phases and split wires are constructed.","PeriodicalId":432063,"journal":{"name":"2022 IEEE 8th International Conference on Energy Smart Systems (ESS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Phase Design and Wires Cross Section Justification of Extra High Voltage Line\",\"authors\":\"M. Bělík, Lykhovyd Yuri, V. Kuchanskyy, O. Rubanenko\",\"doi\":\"10.1109/ESS57819.2022.9969287\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents the results of the analysis of the economic curves of overhead power lines with subsequent justification of the design of the power line. In the paper, economic curves are constructed for a line with a rated voltage of 750 kV. The cross-sections, the use of which is justified depending on the transmitted power, are determined. The analysis of the influence of design parameters on the occurrence of resonant overvoltages in non-sinusoidal overvoltages has been carried out. Three-dimensional graphs of dependences of overvoltage values on changes in the distance between phases and split wires are constructed.\",\"PeriodicalId\":432063,\"journal\":{\"name\":\"2022 IEEE 8th International Conference on Energy Smart Systems (ESS)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE 8th International Conference on Energy Smart Systems (ESS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESS57819.2022.9969287\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 8th International Conference on Energy Smart Systems (ESS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESS57819.2022.9969287","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文给出了架空电力线经济曲线的分析结果,并对架空电力线的设计进行了论证。本文构造了额定电压为750kv的线路的经济曲线。横截面,其使用是合理的取决于发射功率,确定。分析了非正弦过电压中设计参数对谐振过电压发生的影响。建立了过电压值随相距和分线距离变化的三维关系图。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Phase Design and Wires Cross Section Justification of Extra High Voltage Line
The paper presents the results of the analysis of the economic curves of overhead power lines with subsequent justification of the design of the power line. In the paper, economic curves are constructed for a line with a rated voltage of 750 kV. The cross-sections, the use of which is justified depending on the transmitted power, are determined. The analysis of the influence of design parameters on the occurrence of resonant overvoltages in non-sinusoidal overvoltages has been carried out. Three-dimensional graphs of dependences of overvoltage values on changes in the distance between phases and split wires are constructed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信