{"title":"Acrysof IQ Vivity(爱尔康)扩展焦深人工晶状体:植入经验","authors":"L. M. Nizamudinova, V. S. Stebnev, S. D. Stebnev, I. Malov","doi":"10.55531/2072-2354.2023.23.2.8-12","DOIUrl":null,"url":null,"abstract":"Aim to evaluate the results of the AcrySof IQ Vivity (Alcon) extended-focus intraocular lens implantation in cataract surgery with regard to visual acuity at three distances, independence from glasses, severity of photopic phenomena, and patient satisfaction. \nMaterial and methods. 20 patients (20 eyes) with cataract were examined and operated. All patients underwent phacoemulsification with implantation of IOL with extended focus depth AcrySof IQ Vivity, with the following analysis of treatment results. The follow-up period lasted for 6 months. \nResults. In 6 months after surgery, the uncorrected far distance visual acuity was 0.880.04, the middle distance acuity 0.770.01, the near distance acuity 0.610.05. The maximum corrected far distance visual acuity was 0.930.06, the middle distance acuity 0.810.09, near distance acuity 0.650.02. \nConclusion. The IOL provides excellent visual acuity at far and middle distances, as well as functional visual acuity at near distance, which increases the independence from glasses. The target refraction was achieved in 91% of cases. The patients expressed high satisfaction with postoperative results. This lens can be recommended for use in clinical practice.","PeriodicalId":183034,"journal":{"name":"Aspirantskiy Vestnik Povolzhiya","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Acrysof IQ Vivity (Alcon) extended depth-of-focus intraocular lens: implantation experience\",\"authors\":\"L. M. Nizamudinova, V. S. Stebnev, S. D. Stebnev, I. Malov\",\"doi\":\"10.55531/2072-2354.2023.23.2.8-12\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim to evaluate the results of the AcrySof IQ Vivity (Alcon) extended-focus intraocular lens implantation in cataract surgery with regard to visual acuity at three distances, independence from glasses, severity of photopic phenomena, and patient satisfaction. \\nMaterial and methods. 20 patients (20 eyes) with cataract were examined and operated. All patients underwent phacoemulsification with implantation of IOL with extended focus depth AcrySof IQ Vivity, with the following analysis of treatment results. The follow-up period lasted for 6 months. \\nResults. In 6 months after surgery, the uncorrected far distance visual acuity was 0.880.04, the middle distance acuity 0.770.01, the near distance acuity 0.610.05. The maximum corrected far distance visual acuity was 0.930.06, the middle distance acuity 0.810.09, near distance acuity 0.650.02. \\nConclusion. The IOL provides excellent visual acuity at far and middle distances, as well as functional visual acuity at near distance, which increases the independence from glasses. The target refraction was achieved in 91% of cases. The patients expressed high satisfaction with postoperative results. This lens can be recommended for use in clinical practice.\",\"PeriodicalId\":183034,\"journal\":{\"name\":\"Aspirantskiy Vestnik Povolzhiya\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Aspirantskiy Vestnik Povolzhiya\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.55531/2072-2354.2023.23.2.8-12\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aspirantskiy Vestnik Povolzhiya","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55531/2072-2354.2023.23.2.8-12","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的评价AcrySof IQ Vivity (Alcon)大聚焦人工晶状体植入术在白内障手术中的三距离视力、脱离眼镜的独立性、光现象的严重程度和患者满意度。材料和方法。对20例(20眼)白内障患者进行了检查和手术。所有患者均行超声乳化术合并人工晶状体植入术,扩大晶状体聚焦深度,对治疗结果分析如下:随访6个月。结果。术后6个月,未矫正远视力0.880.04,中距离视力0.770.01,近距离视力0.610.05。最大矫正远视力为0.930.06,中视力为0.810.09,近视力为0.650.02。结论。人工晶状体提供了良好的中远距离视力,以及近距离的功能性视力,增加了对眼镜的独立性。91%的病例达到了目标屈光。患者对术后效果满意。这种晶状体可推荐用于临床实践。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Acrysof IQ Vivity (Alcon) extended depth-of-focus intraocular lens: implantation experience
Aim to evaluate the results of the AcrySof IQ Vivity (Alcon) extended-focus intraocular lens implantation in cataract surgery with regard to visual acuity at three distances, independence from glasses, severity of photopic phenomena, and patient satisfaction. Material and methods. 20 patients (20 eyes) with cataract were examined and operated. All patients underwent phacoemulsification with implantation of IOL with extended focus depth AcrySof IQ Vivity, with the following analysis of treatment results. The follow-up period lasted for 6 months. Results. In 6 months after surgery, the uncorrected far distance visual acuity was 0.880.04, the middle distance acuity 0.770.01, the near distance acuity 0.610.05. The maximum corrected far distance visual acuity was 0.930.06, the middle distance acuity 0.810.09, near distance acuity 0.650.02. Conclusion. The IOL provides excellent visual acuity at far and middle distances, as well as functional visual acuity at near distance, which increases the independence from glasses. The target refraction was achieved in 91% of cases. The patients expressed high satisfaction with postoperative results. This lens can be recommended for use in clinical practice.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信