基于相对增益阵列原理的FACTS控制器交互分析

H. Li, P. Dong, M. Liu, Q. Wang
{"title":"基于相对增益阵列原理的FACTS控制器交互分析","authors":"H. Li, P. Dong, M. Liu, Q. Wang","doi":"10.1109/PESA.2011.5982887","DOIUrl":null,"url":null,"abstract":"With aggravation of power system complexity and wide application of flexible AC transmission system (FACTS) equipments in power system, interactions and coordination between FACTS controllers need to be investigated and solved. Different from Phillips-Heffron model, the linear model of 2-area, 4-machine power system with Static Var Compensators (SVC) and Static Synchronous Compensators (STATCOM) installed was established, which is used in the process of relative gain array (RGA) analysis. The relationship of interactions and electric distance between SVC and SVC or between SVC and STATCOM were investigated based on RGA principle. The results of a time-domain simulation was consistent with RGA analysis, which verified the feasibility and effectiveness of RGA principle used to analyze interactions between FACTS equipments in power system.","PeriodicalId":288978,"journal":{"name":"2011 4th International Conference on Power Electronics Systems and Applications","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Interaction analysis of FACTS controllers based on relative gain array principle\",\"authors\":\"H. Li, P. Dong, M. Liu, Q. Wang\",\"doi\":\"10.1109/PESA.2011.5982887\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With aggravation of power system complexity and wide application of flexible AC transmission system (FACTS) equipments in power system, interactions and coordination between FACTS controllers need to be investigated and solved. Different from Phillips-Heffron model, the linear model of 2-area, 4-machine power system with Static Var Compensators (SVC) and Static Synchronous Compensators (STATCOM) installed was established, which is used in the process of relative gain array (RGA) analysis. The relationship of interactions and electric distance between SVC and SVC or between SVC and STATCOM were investigated based on RGA principle. The results of a time-domain simulation was consistent with RGA analysis, which verified the feasibility and effectiveness of RGA principle used to analyze interactions between FACTS equipments in power system.\",\"PeriodicalId\":288978,\"journal\":{\"name\":\"2011 4th International Conference on Power Electronics Systems and Applications\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 4th International Conference on Power Electronics Systems and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESA.2011.5982887\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 4th International Conference on Power Electronics Systems and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESA.2011.5982887","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

随着电力系统复杂性的加剧和柔性交流输电系统(FACTS)设备在电力系统中的广泛应用,需要研究和解决FACTS控制器之间的相互作用和协调问题。与philips - heffron模型不同,本文建立了安装静态无功补偿器(SVC)和静态同步补偿器(STATCOM)的2区4机电力系统的线性模型,并将其用于相对增益阵列(RGA)分析过程。基于RGA原理研究了SVC与SVC、SVC与STATCOM之间的相互作用与电距离的关系。时域仿真结果与RGA分析结果一致,验证了RGA原理用于电力系统FACTS设备相互作用分析的可行性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Interaction analysis of FACTS controllers based on relative gain array principle
With aggravation of power system complexity and wide application of flexible AC transmission system (FACTS) equipments in power system, interactions and coordination between FACTS controllers need to be investigated and solved. Different from Phillips-Heffron model, the linear model of 2-area, 4-machine power system with Static Var Compensators (SVC) and Static Synchronous Compensators (STATCOM) installed was established, which is used in the process of relative gain array (RGA) analysis. The relationship of interactions and electric distance between SVC and SVC or between SVC and STATCOM were investigated based on RGA principle. The results of a time-domain simulation was consistent with RGA analysis, which verified the feasibility and effectiveness of RGA principle used to analyze interactions between FACTS equipments in power system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信