{"title":"马来西亚圣士大学工程校园图书馆室内空气质量评价","authors":"Maher Elbayoum,, N. Ramli, N. F. M. Md Yusof, Norrimi Rosaida Awang, N. S. Zainordin, Maisarah Sulaiman, S. Shith, Teh Nur Amalina Zaki","doi":"10.52865/nvhy1702","DOIUrl":null,"url":null,"abstract":"The indoor air quality (IAQ) in micro-environments is extremely important due to its impact on health and productivity of students. This study presents the findings of indoor air quality (IAQ) investigations in engineering campus library at the University Sains Malaysia. Four levels of the library were investigated during May 2015. Measurements were carried out by using electrochemical analyzer and hand-held particulate matter (PM) instrument. The results showed that Formaldehyde, carbon monoxide (CO), Ozone, and total volatile organic compounds (TVOC) levels were found below Malaysian guideline values. Temperature ranged between 18.9–28.4 °C and relative humidity (RH) ranged between 49%–73% with an average of 62.2%. The indoor concentration PM2.5 level was 5.73±4.93μg/m3. All the monitoring pollutants’ levels were found below Malaysian guideline values in the ground floor, and the 1st and 2nd floors. However, several exceedances occurred in the 3rd floor. Inadequate introduction and/or distribution of fresh air may be the main problem in the left side of the building and in the 3rd floor. Thus, evaluation of the HVAC (Heating, Ventilation, and Air Conditioning) system should be examined","PeriodicalId":223912,"journal":{"name":"Israa University Journal for Applied Science","volume":"195 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Evaluation of Indoor Air Quality at Engineering Campus Library at the University Sains Malaysia\",\"authors\":\"Maher Elbayoum,, N. Ramli, N. F. M. Md Yusof, Norrimi Rosaida Awang, N. S. Zainordin, Maisarah Sulaiman, S. Shith, Teh Nur Amalina Zaki\",\"doi\":\"10.52865/nvhy1702\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The indoor air quality (IAQ) in micro-environments is extremely important due to its impact on health and productivity of students. This study presents the findings of indoor air quality (IAQ) investigations in engineering campus library at the University Sains Malaysia. Four levels of the library were investigated during May 2015. Measurements were carried out by using electrochemical analyzer and hand-held particulate matter (PM) instrument. The results showed that Formaldehyde, carbon monoxide (CO), Ozone, and total volatile organic compounds (TVOC) levels were found below Malaysian guideline values. Temperature ranged between 18.9–28.4 °C and relative humidity (RH) ranged between 49%–73% with an average of 62.2%. The indoor concentration PM2.5 level was 5.73±4.93μg/m3. All the monitoring pollutants’ levels were found below Malaysian guideline values in the ground floor, and the 1st and 2nd floors. However, several exceedances occurred in the 3rd floor. Inadequate introduction and/or distribution of fresh air may be the main problem in the left side of the building and in the 3rd floor. Thus, evaluation of the HVAC (Heating, Ventilation, and Air Conditioning) system should be examined\",\"PeriodicalId\":223912,\"journal\":{\"name\":\"Israa University Journal for Applied Science\",\"volume\":\"195 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Israa University Journal for Applied Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52865/nvhy1702\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Israa University Journal for Applied Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52865/nvhy1702","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

微环境中的室内空气质量对学生的健康和学习能力有着极其重要的影响。本研究介绍了马来西亚理科大学工程校园图书馆室内空气质量(IAQ)调查的结果。2015年5月对图书馆的四层进行了调查。采用电化学分析仪和手持式颗粒物(PM)测定仪进行测量。结果显示,甲醛、一氧化碳(CO)、臭氧和总挥发性有机化合物(TVOC)的含量低于马来西亚的指导值。温度范围为18.9 ~ 28.4℃,相对湿度范围为49% ~ 73%,平均为62.2%。室内PM2.5浓度为5.73±4.93μg/m3。在一楼、一楼和二楼,所有监测到的污染物水平都低于马来西亚的指导值。然而,三楼发生了几起超标事件。引入和/或分配新鲜空气不足可能是建筑物左侧和三楼的主要问题。因此,应该检查HVAC(采暖、通风和空调)系统的评估
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of Indoor Air Quality at Engineering Campus Library at the University Sains Malaysia
The indoor air quality (IAQ) in micro-environments is extremely important due to its impact on health and productivity of students. This study presents the findings of indoor air quality (IAQ) investigations in engineering campus library at the University Sains Malaysia. Four levels of the library were investigated during May 2015. Measurements were carried out by using electrochemical analyzer and hand-held particulate matter (PM) instrument. The results showed that Formaldehyde, carbon monoxide (CO), Ozone, and total volatile organic compounds (TVOC) levels were found below Malaysian guideline values. Temperature ranged between 18.9–28.4 °C and relative humidity (RH) ranged between 49%–73% with an average of 62.2%. The indoor concentration PM2.5 level was 5.73±4.93μg/m3. All the monitoring pollutants’ levels were found below Malaysian guideline values in the ground floor, and the 1st and 2nd floors. However, several exceedances occurred in the 3rd floor. Inadequate introduction and/or distribution of fresh air may be the main problem in the left side of the building and in the 3rd floor. Thus, evaluation of the HVAC (Heating, Ventilation, and Air Conditioning) system should be examined
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信