优化局部射频热疗的混合频率方法

H. Kok, G. van Stam, A. Bel, J. Crezee
{"title":"优化局部射频热疗的混合频率方法","authors":"H. Kok, G. van Stam, A. Bel, J. Crezee","doi":"10.1109/EUMC.2015.7345878","DOIUrl":null,"url":null,"abstract":"Locoregional hyperthermia is usually performed using phased-array systems, consisting of multiple RF antennas operating at a single frequency. This study investigated the use of a mixed frequency approach to improve the quality of heating. Simulations in a homogeneous phantom and in 5 patient anatomies were performed for systems consisting of rectangular waveguides operating at 70 and 140 MHz. Phantom results were very promising and showed a 20% lower superficial SAR deposition compared to the central target region for a 3-ring system with the central ring consisting of 140 MHz waveguides and the other two rings consisting of 70 MHz waveguides. In patient anatomies however, this benefit did not last, so further research is required to determine the optimal mixed frequency strategy for clinical use.","PeriodicalId":350086,"journal":{"name":"2015 European Microwave Conference (EuMC)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"A mixed frequency approach to optimize locoregional RF hyperthermia\",\"authors\":\"H. Kok, G. van Stam, A. Bel, J. Crezee\",\"doi\":\"10.1109/EUMC.2015.7345878\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Locoregional hyperthermia is usually performed using phased-array systems, consisting of multiple RF antennas operating at a single frequency. This study investigated the use of a mixed frequency approach to improve the quality of heating. Simulations in a homogeneous phantom and in 5 patient anatomies were performed for systems consisting of rectangular waveguides operating at 70 and 140 MHz. Phantom results were very promising and showed a 20% lower superficial SAR deposition compared to the central target region for a 3-ring system with the central ring consisting of 140 MHz waveguides and the other two rings consisting of 70 MHz waveguides. In patient anatomies however, this benefit did not last, so further research is required to determine the optimal mixed frequency strategy for clinical use.\",\"PeriodicalId\":350086,\"journal\":{\"name\":\"2015 European Microwave Conference (EuMC)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 European Microwave Conference (EuMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUMC.2015.7345878\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 European Microwave Conference (EuMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUMC.2015.7345878","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

局部热疗通常使用相控阵系统进行,该系统由多个以单一频率工作的射频天线组成。本研究探讨了使用混合频率方法来提高加热质量。模拟在一个均匀的幻影和5个病人解剖进行了系统组成的矩形波导工作在70和140 MHz。幻影结果非常有希望,与中心目标区域相比,中心环由140 MHz波导组成,另外两个环由70 MHz波导组成的三环系统的表面SAR沉积降低了20%。然而,在患者解剖中,这种益处并没有持续下去,因此需要进一步的研究来确定临床使用的最佳混合频率策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A mixed frequency approach to optimize locoregional RF hyperthermia
Locoregional hyperthermia is usually performed using phased-array systems, consisting of multiple RF antennas operating at a single frequency. This study investigated the use of a mixed frequency approach to improve the quality of heating. Simulations in a homogeneous phantom and in 5 patient anatomies were performed for systems consisting of rectangular waveguides operating at 70 and 140 MHz. Phantom results were very promising and showed a 20% lower superficial SAR deposition compared to the central target region for a 3-ring system with the central ring consisting of 140 MHz waveguides and the other two rings consisting of 70 MHz waveguides. In patient anatomies however, this benefit did not last, so further research is required to determine the optimal mixed frequency strategy for clinical use.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信