用于记录心电和心电信号的电子传感器系统

Krasimir Cheshmedzhiev, Evgeniya Gospodinova, Mitko Gospodinov, Penio Lebamovski
{"title":"用于记录心电和心电信号的电子传感器系统","authors":"Krasimir Cheshmedzhiev, Evgeniya Gospodinova, Mitko Gospodinov, Penio Lebamovski","doi":"10.1145/3472410.3472422","DOIUrl":null,"url":null,"abstract":"The creation of portable devices for preventive, non-invasive control of the cardiac indicators of the individual is one of the main tasks of medical electronics. The integration of sensors, microcontrollers and interfaces in a compact portable form allows for continuous monitoring of patients with cardiac diseases in order to respond quickly and adequately in critical situations. The article presents an electronic sensor system for synchronous registration of electrocardiography (ECG) and photoplethysmography (PPG) signals, which are subsequently analyzed through developed authoring software. Based on the comparative analysis of the determined heart rate intervals (RR / PP intervals) in terms of the accuracy parameter, it follows that both types of signals: ECG and PPG are suitable for examining the cardiac status of patients, with a relative error being smaller than 3%.","PeriodicalId":115575,"journal":{"name":"Proceedings of the 22nd International Conference on Computer Systems and Technologies","volume":"99 21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Electronic sensor system for registering ECG and PPG signals\",\"authors\":\"Krasimir Cheshmedzhiev, Evgeniya Gospodinova, Mitko Gospodinov, Penio Lebamovski\",\"doi\":\"10.1145/3472410.3472422\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The creation of portable devices for preventive, non-invasive control of the cardiac indicators of the individual is one of the main tasks of medical electronics. The integration of sensors, microcontrollers and interfaces in a compact portable form allows for continuous monitoring of patients with cardiac diseases in order to respond quickly and adequately in critical situations. The article presents an electronic sensor system for synchronous registration of electrocardiography (ECG) and photoplethysmography (PPG) signals, which are subsequently analyzed through developed authoring software. Based on the comparative analysis of the determined heart rate intervals (RR / PP intervals) in terms of the accuracy parameter, it follows that both types of signals: ECG and PPG are suitable for examining the cardiac status of patients, with a relative error being smaller than 3%.\",\"PeriodicalId\":115575,\"journal\":{\"name\":\"Proceedings of the 22nd International Conference on Computer Systems and Technologies\",\"volume\":\"99 21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-06-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 22nd International Conference on Computer Systems and Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/3472410.3472422\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 22nd International Conference on Computer Systems and Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3472410.3472422","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

创建便携式设备的预防性,非侵入性控制个人的心脏指标是医疗电子学的主要任务之一。将传感器、微控制器和接口集成在一个紧凑的便携式形式中,可以对心脏病患者进行持续监测,以便在危急情况下迅速和充分地作出反应。本文介绍了一种用于同步配准心电图(ECG)和光容积脉搏波(PPG)信号的电子传感器系统,随后通过开发的创作软件对其进行分析。通过对确定的心率间隔(RR / PP间隔)在准确率参数上的对比分析,可以得出ECG和PPG两种信号都适合用于检测患者的心脏状态,相对误差均小于3%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electronic sensor system for registering ECG and PPG signals
The creation of portable devices for preventive, non-invasive control of the cardiac indicators of the individual is one of the main tasks of medical electronics. The integration of sensors, microcontrollers and interfaces in a compact portable form allows for continuous monitoring of patients with cardiac diseases in order to respond quickly and adequately in critical situations. The article presents an electronic sensor system for synchronous registration of electrocardiography (ECG) and photoplethysmography (PPG) signals, which are subsequently analyzed through developed authoring software. Based on the comparative analysis of the determined heart rate intervals (RR / PP intervals) in terms of the accuracy parameter, it follows that both types of signals: ECG and PPG are suitable for examining the cardiac status of patients, with a relative error being smaller than 3%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信