{"title":"便携式ADSS表面污染计","authors":"K. S. Edwards, P. Pedrow, R. Olsen","doi":"10.1109/CEIDP.1999.804615","DOIUrl":null,"url":null,"abstract":"All dielectric self-supporting (ADSS) fiber optic cable is known to have a limited installation lifetime in some environments when installed near high voltage transmission lines. Dry band arcing has been identified as a contributing factor in the short service life for some of these cables. It has been hypothesized that contamination on the jacket of the fiber optic cable will be an indicator of cable installations that will have a short service life. In this work a portable transducer for measuring contamination levels on the jacket of ADSS cable is being designed, constructed and calibrated in a high voltage environment. The transducer will be designed to operate in both wet and dry conditions. It will measure the electrical resistance per meter of contaminated in-service ADSS fiber optic cable. The transducer will be effective in the range 10/sup 5/ to 10/sup 7/ /spl Omega//m. It will be computer controlled thus requiring little intervention by the operator. This research will include laboratory scale tests with ADSS cable and a 365 kV AC power supply.","PeriodicalId":267509,"journal":{"name":"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)","volume":"72 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Portable ADSS surface contamination meter\",\"authors\":\"K. S. Edwards, P. Pedrow, R. Olsen\",\"doi\":\"10.1109/CEIDP.1999.804615\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"All dielectric self-supporting (ADSS) fiber optic cable is known to have a limited installation lifetime in some environments when installed near high voltage transmission lines. Dry band arcing has been identified as a contributing factor in the short service life for some of these cables. It has been hypothesized that contamination on the jacket of the fiber optic cable will be an indicator of cable installations that will have a short service life. In this work a portable transducer for measuring contamination levels on the jacket of ADSS cable is being designed, constructed and calibrated in a high voltage environment. The transducer will be designed to operate in both wet and dry conditions. It will measure the electrical resistance per meter of contaminated in-service ADSS fiber optic cable. The transducer will be effective in the range 10/sup 5/ to 10/sup 7/ /spl Omega//m. It will be computer controlled thus requiring little intervention by the operator. This research will include laboratory scale tests with ADSS cable and a 365 kV AC power supply.\",\"PeriodicalId\":267509,\"journal\":{\"name\":\"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)\",\"volume\":\"72 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.1999.804615\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1999.804615","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

全介质自支撑(ADSS)光纤电缆在高压输电线路附近安装时,在某些环境中具有有限的安装寿命。干带电弧已被确定为一些电缆使用寿命短的一个因素。据推测,光纤电缆护套上的污染将是电缆装置使用寿命短的一个指标。在这项工作中,正在设计、制造和校准一种便携式传感器,用于测量高压环境下ADSS电缆外壳上的污染水平。换能器将被设计为在潮湿和干燥条件下工作。它将测量在使用中被污染的ADSS光纤电缆每米的电阻。换能器将在10/sup 5/至10/sup 7/ /spl ω //m范围内有效。它将由计算机控制,因此几乎不需要操作员的干预。这项研究将包括使用ADSS电缆和365千伏交流电源进行实验室规模的测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Portable ADSS surface contamination meter
All dielectric self-supporting (ADSS) fiber optic cable is known to have a limited installation lifetime in some environments when installed near high voltage transmission lines. Dry band arcing has been identified as a contributing factor in the short service life for some of these cables. It has been hypothesized that contamination on the jacket of the fiber optic cable will be an indicator of cable installations that will have a short service life. In this work a portable transducer for measuring contamination levels on the jacket of ADSS cable is being designed, constructed and calibrated in a high voltage environment. The transducer will be designed to operate in both wet and dry conditions. It will measure the electrical resistance per meter of contaminated in-service ADSS fiber optic cable. The transducer will be effective in the range 10/sup 5/ to 10/sup 7/ /spl Omega//m. It will be computer controlled thus requiring little intervention by the operator. This research will include laboratory scale tests with ADSS cable and a 365 kV AC power supply.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信