{"title":"UPFC对亚齐150kv输电系统潮流影响分析","authors":"Rahmatul Akbar, I. D. Sara, Suriadi","doi":"10.1109/COSITE52651.2021.9649452","DOIUrl":null,"url":null,"abstract":"The electrical energy transmission line is a series of electric power distribution from the generator to the distribution line. The transmission of electrical energy often suffer losses with the appearance of current on the neutral side due to unbalance power flow on three phase system. The controlling of this power flow is very difficult, it required a system to overcome these problems. In this study, Flexible AC Transmission System (FACTS) equipment, namely UPFC (Unified Power Flow Control) was used to control power flow in the 150 kV Aceh transmission sub system. The calculation is obtained based on the Continuation Power Flow (CPF) method, the voltage profile is observed in graphical form to see the condition of the voltage profile when it reaches the Maximum Loading Parameter (MLP). The preliminary results of CPF simulation refer to the base power (MVA $\\mathbf{Base}=100$ MVA) and the base voltage $(\\mathbf{V}\\ \\mathbf{Base}=150\\mathbf{kV})$ obtained losses on the active power (P) of 0.97 p.u, and it decreased to 0.20 p.u after UPFC installation. While the reactive power (Q) obtained quite large losses of 4.21 p. u. on CPF simulation, and it decreased to 0.91 p.u. after UPFC installation.","PeriodicalId":399316,"journal":{"name":"2021 International Conference on Computer System, Information Technology, and Electrical Engineering (COSITE)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Analysis of UPFC Installation Effect on Power Flow in the 150 kV Aceh Transmission System\",\"authors\":\"Rahmatul Akbar, I. D. Sara, Suriadi\",\"doi\":\"10.1109/COSITE52651.2021.9649452\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The electrical energy transmission line is a series of electric power distribution from the generator to the distribution line. The transmission of electrical energy often suffer losses with the appearance of current on the neutral side due to unbalance power flow on three phase system. The controlling of this power flow is very difficult, it required a system to overcome these problems. In this study, Flexible AC Transmission System (FACTS) equipment, namely UPFC (Unified Power Flow Control) was used to control power flow in the 150 kV Aceh transmission sub system. The calculation is obtained based on the Continuation Power Flow (CPF) method, the voltage profile is observed in graphical form to see the condition of the voltage profile when it reaches the Maximum Loading Parameter (MLP). The preliminary results of CPF simulation refer to the base power (MVA $\\\\mathbf{Base}=100$ MVA) and the base voltage $(\\\\mathbf{V}\\\\ \\\\mathbf{Base}=150\\\\mathbf{kV})$ obtained losses on the active power (P) of 0.97 p.u, and it decreased to 0.20 p.u after UPFC installation. While the reactive power (Q) obtained quite large losses of 4.21 p. u. on CPF simulation, and it decreased to 0.91 p.u. after UPFC installation.\",\"PeriodicalId\":399316,\"journal\":{\"name\":\"2021 International Conference on Computer System, Information Technology, and Electrical Engineering (COSITE)\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Computer System, Information Technology, and Electrical Engineering (COSITE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/COSITE52651.2021.9649452\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Computer System, Information Technology, and Electrical Engineering (COSITE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COSITE52651.2021.9649452","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

电能传输线是从发电机到配电线路的一系列电能分配。在三相系统中,由于潮流不平衡,电能的传输往往会出现中性点侧电流的损失。这种潮流的控制是非常困难的,它需要一个系统来克服这些问题。在本研究中,采用柔性交流输电系统(FACTS)设备,即UPFC(统一潮流控制)来控制150 kV亚齐输电分系统的潮流。采用连续潮流法(CPF)进行计算,以图形形式观察电压分布,观察电压分布达到最大负载参数(MLP)时的情况。CPF仿真的初步结果为基极功率(MVA $\mathbf{base}=100$ MVA)和基极电压$(\mathbf{V}\ \mathbf{base}=150\mathbf{kV})$,得到有功功率(P)的损耗为0.97 p.u,安装UPFC后损耗降至0.20 p.u。而无功功率(Q)在CPF模拟中得到了相当大的损失,为4.21 p.u.,安装UPFC后降至0.91 p.u.。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of UPFC Installation Effect on Power Flow in the 150 kV Aceh Transmission System
The electrical energy transmission line is a series of electric power distribution from the generator to the distribution line. The transmission of electrical energy often suffer losses with the appearance of current on the neutral side due to unbalance power flow on three phase system. The controlling of this power flow is very difficult, it required a system to overcome these problems. In this study, Flexible AC Transmission System (FACTS) equipment, namely UPFC (Unified Power Flow Control) was used to control power flow in the 150 kV Aceh transmission sub system. The calculation is obtained based on the Continuation Power Flow (CPF) method, the voltage profile is observed in graphical form to see the condition of the voltage profile when it reaches the Maximum Loading Parameter (MLP). The preliminary results of CPF simulation refer to the base power (MVA $\mathbf{Base}=100$ MVA) and the base voltage $(\mathbf{V}\ \mathbf{Base}=150\mathbf{kV})$ obtained losses on the active power (P) of 0.97 p.u, and it decreased to 0.20 p.u after UPFC installation. While the reactive power (Q) obtained quite large losses of 4.21 p. u. on CPF simulation, and it decreased to 0.91 p.u. after UPFC installation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信