采用0.18μm CMOS技术的2μW生物医学前端和ΣΔ ADC,适用于自供电u -医疗设备

P. Jha, P. Patra, J. Naik, A. Dutta, A. Acharyya, P. Rajalakshmi, S. Singh
{"title":"采用0.18μm CMOS技术的2μW生物医学前端和ΣΔ ADC,适用于自供电u -医疗设备","authors":"P. Jha, P. Patra, J. Naik, A. Dutta, A. Acharyya, P. Rajalakshmi, S. Singh","doi":"10.1109/NEWCAS.2015.7182054","DOIUrl":null,"url":null,"abstract":"This paper presents an ultra-low power analog front end (AFE) with ΣΔ modulator ADC meant for acquisition of biopotential signals. The system consists of a signal conditioning stage with programmable gain and bandwidth, a mixed signal automatic gain control (AGC), and a ΣΔ ADC. The full system is designed in UMC 18μm CMOS. The AFE achieves an overall linearity of more 10 bits with 0.47μW power consumption. The ADC provides 2nd order noise shaping while using single integrator and an ENOB of ~12 bits with 1.4μW power consumption. The system was successfully tested for a ECG signal from PTB database.","PeriodicalId":404655,"journal":{"name":"2015 IEEE 13th International New Circuits and Systems Conference (NEWCAS)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A 2μW biomedical frontend with ΣΔ ADC for self-powered U-healthcare devices in 0.18μm CMOS technology\",\"authors\":\"P. Jha, P. Patra, J. Naik, A. Dutta, A. Acharyya, P. Rajalakshmi, S. Singh\",\"doi\":\"10.1109/NEWCAS.2015.7182054\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an ultra-low power analog front end (AFE) with ΣΔ modulator ADC meant for acquisition of biopotential signals. The system consists of a signal conditioning stage with programmable gain and bandwidth, a mixed signal automatic gain control (AGC), and a ΣΔ ADC. The full system is designed in UMC 18μm CMOS. The AFE achieves an overall linearity of more 10 bits with 0.47μW power consumption. The ADC provides 2nd order noise shaping while using single integrator and an ENOB of ~12 bits with 1.4μW power consumption. The system was successfully tested for a ECG signal from PTB database.\",\"PeriodicalId\":404655,\"journal\":{\"name\":\"2015 IEEE 13th International New Circuits and Systems Conference (NEWCAS)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 13th International New Circuits and Systems Conference (NEWCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEWCAS.2015.7182054\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 13th International New Circuits and Systems Conference (NEWCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEWCAS.2015.7182054","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文提出了一种超低功耗模拟前端(AFE)与ΣΔ调制器ADC用于采集生物电位信号。该系统由具有可编程增益和带宽的信号调理级、混合信号自动增益控制(AGC)和ΣΔ ADC组成。整个系统采用UMC 18μm CMOS设计。该AFE在0.47μW功耗下实现了10位以上的整体线性度。该ADC提供二阶噪声整形,采用单积分器,ENOB为~12位,功耗为1.4μW。该系统成功地对PTB数据库中的心电信号进行了测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A 2μW biomedical frontend with ΣΔ ADC for self-powered U-healthcare devices in 0.18μm CMOS technology
This paper presents an ultra-low power analog front end (AFE) with ΣΔ modulator ADC meant for acquisition of biopotential signals. The system consists of a signal conditioning stage with programmable gain and bandwidth, a mixed signal automatic gain control (AGC), and a ΣΔ ADC. The full system is designed in UMC 18μm CMOS. The AFE achieves an overall linearity of more 10 bits with 0.47μW power consumption. The ADC provides 2nd order noise shaping while using single integrator and an ENOB of ~12 bits with 1.4μW power consumption. The system was successfully tested for a ECG signal from PTB database.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信