{"title":"磁粉成像的系统校准单元:系统矩阵","authors":"A. Halkola, J. Rahmer, B. Gleich, J. Borgert, T. Buzug","doi":"10.1109/IWMPI.2013.6528344","DOIUrl":null,"url":null,"abstract":"Magnetic particle imaging (MPI) has the potential to deliver images at high time resolution and submillimetre spatial resolution. In order to reconstruct the images from the measured data one needs to obtain a so called system matrix. A system matrix can be measured by physically moving a voxel sized sample and measuring the signal at each position within the imaging volume of the scanner. A system calibration unit (SCU) provides a fast and efficient method to measure a system matrix. The physical movement of the sample can be replaced by the use of homogeneous focus fields. This resulted in time saving of a factor of 2-3. In this paper, the use of sensitive dedicated receive coils is described that provide a further improvement by up to an order of magnitude in sensitivity.","PeriodicalId":267566,"journal":{"name":"2013 International Workshop on Magnetic Particle Imaging (IWMPI)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"System calibration unit for magnetic particle imaging: System matrix\",\"authors\":\"A. Halkola, J. Rahmer, B. Gleich, J. Borgert, T. Buzug\",\"doi\":\"10.1109/IWMPI.2013.6528344\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Magnetic particle imaging (MPI) has the potential to deliver images at high time resolution and submillimetre spatial resolution. In order to reconstruct the images from the measured data one needs to obtain a so called system matrix. A system matrix can be measured by physically moving a voxel sized sample and measuring the signal at each position within the imaging volume of the scanner. A system calibration unit (SCU) provides a fast and efficient method to measure a system matrix. The physical movement of the sample can be replaced by the use of homogeneous focus fields. This resulted in time saving of a factor of 2-3. In this paper, the use of sensitive dedicated receive coils is described that provide a further improvement by up to an order of magnitude in sensitivity.\",\"PeriodicalId\":267566,\"journal\":{\"name\":\"2013 International Workshop on Magnetic Particle Imaging (IWMPI)\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-03-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 International Workshop on Magnetic Particle Imaging (IWMPI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IWMPI.2013.6528344\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Workshop on Magnetic Particle Imaging (IWMPI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWMPI.2013.6528344","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

磁颗粒成像(MPI)具有提供高时间分辨率和亚毫米空间分辨率图像的潜力。为了从测量数据重建图像,需要得到一个所谓的系统矩阵。系统矩阵可以通过物理移动体素大小的样品并测量扫描仪成像体积内每个位置的信号来测量。系统校准单元(SCU)提供了一种快速有效的测量系统矩阵的方法。样品的物理运动可以通过使用均匀焦点场来代替。这节省了2-3倍的时间。在本文中,描述了使用灵敏的专用接收线圈,该线圈提供了灵敏度上一个数量级的进一步改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
System calibration unit for magnetic particle imaging: System matrix
Magnetic particle imaging (MPI) has the potential to deliver images at high time resolution and submillimetre spatial resolution. In order to reconstruct the images from the measured data one needs to obtain a so called system matrix. A system matrix can be measured by physically moving a voxel sized sample and measuring the signal at each position within the imaging volume of the scanner. A system calibration unit (SCU) provides a fast and efficient method to measure a system matrix. The physical movement of the sample can be replaced by the use of homogeneous focus fields. This resulted in time saving of a factor of 2-3. In this paper, the use of sensitive dedicated receive coils is described that provide a further improvement by up to an order of magnitude in sensitivity.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信