一种基于阻抗法的串联电弧故障定位算法

E. Calderon, P. Schweitzer, S. Weber
{"title":"一种基于阻抗法的串联电弧故障定位算法","authors":"E. Calderon, P. Schweitzer, S. Weber","doi":"10.1109/HOLM.2017.8088105","DOIUrl":null,"url":null,"abstract":"This article describes a fault location method, developed within our laboratory, which uses the physical parameters of an electrical line to estimate the series arc fault distance in an experimental short indoor power line. The method estimates currents at several hypothetical fault points on the line, using recorded data at both ends of the indoor power line, by looking for a current difference minimization. The test bench used for our purpose is composed of a 49 meter indoor power line used in domestic networks (220V-50Hz) and a 47 ohm power resistor load. An arc fault (carbonized path) can be inserted at many different points (40 are available) across the line.","PeriodicalId":354484,"journal":{"name":"2017 IEEE Holm Conference on Electrical Contacts","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A series arc fault location algorithm based on an impedance method for a domestic AC system\",\"authors\":\"E. Calderon, P. Schweitzer, S. Weber\",\"doi\":\"10.1109/HOLM.2017.8088105\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article describes a fault location method, developed within our laboratory, which uses the physical parameters of an electrical line to estimate the series arc fault distance in an experimental short indoor power line. The method estimates currents at several hypothetical fault points on the line, using recorded data at both ends of the indoor power line, by looking for a current difference minimization. The test bench used for our purpose is composed of a 49 meter indoor power line used in domestic networks (220V-50Hz) and a 47 ohm power resistor load. An arc fault (carbonized path) can be inserted at many different points (40 are available) across the line.\",\"PeriodicalId\":354484,\"journal\":{\"name\":\"2017 IEEE Holm Conference on Electrical Contacts\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE Holm Conference on Electrical Contacts\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HOLM.2017.8088105\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Holm Conference on Electrical Contacts","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HOLM.2017.8088105","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文介绍了我们实验室开发的一种故障定位方法,该方法利用电气线路的物理参数来估计实验室内短线的串联电弧故障距离。该方法利用室内电力线两端的记录数据,通过寻找电流差最小化来估计线路上几个假设故障点的电流。用于我们目的的试验台由国内网络(220V-50Hz)使用的49米室内电力线和47欧姆功率电阻负载组成。电弧故障(碳化路径)可以在线路上的许多不同点(40个可用点)插入。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A series arc fault location algorithm based on an impedance method for a domestic AC system
This article describes a fault location method, developed within our laboratory, which uses the physical parameters of an electrical line to estimate the series arc fault distance in an experimental short indoor power line. The method estimates currents at several hypothetical fault points on the line, using recorded data at both ends of the indoor power line, by looking for a current difference minimization. The test bench used for our purpose is composed of a 49 meter indoor power line used in domestic networks (220V-50Hz) and a 47 ohm power resistor load. An arc fault (carbonized path) can be inserted at many different points (40 are available) across the line.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信