基于全模型和简化模型EKF的永磁同步电机无传感器直接转矩位置和速度估计器的比较

V. Muzikova, T. Glasberger, V. Šmídl, Z. Peroutka
{"title":"基于全模型和简化模型EKF的永磁同步电机无传感器直接转矩位置和速度估计器的比较","authors":"V. Muzikova, T. Glasberger, V. Šmídl, Z. Peroutka","doi":"10.1109/AE.2014.7011706","DOIUrl":null,"url":null,"abstract":"The aim of this paper is to study the use of the Extended Kalman filer (EKF) for sensorless control of a permanent magnet synchronous motor (PMSM) drive controlled by direct torque control (DTC). The main drawback of DTC is the necessity of short sampling period. The challenge for the EKF is therefore the minimization of its execution time. This is achieved by using so called reduced state space model of the drive with only two state variables, the rotor speed and the rotor position. It is proved by simulations and experiments that the EKF with this reduced model has the same performance as the four-dimensional full state space model at much lower computational cost. The sensorless DTC with the reduced model EKF was found to be equal to DTC with the full model EKF in terms of performance and superior in terms of computational cost. All experiments were carried out on a laboratory prototype of the drive with rated power of 250 W.","PeriodicalId":149779,"journal":{"name":"2014 International Conference on Applied Electronics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Comparison of full-model and reduced-model EKF based position and speed estimators for sensorless DTC of permanent magnet synchronous machines\",\"authors\":\"V. Muzikova, T. Glasberger, V. Šmídl, Z. Peroutka\",\"doi\":\"10.1109/AE.2014.7011706\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this paper is to study the use of the Extended Kalman filer (EKF) for sensorless control of a permanent magnet synchronous motor (PMSM) drive controlled by direct torque control (DTC). The main drawback of DTC is the necessity of short sampling period. The challenge for the EKF is therefore the minimization of its execution time. This is achieved by using so called reduced state space model of the drive with only two state variables, the rotor speed and the rotor position. It is proved by simulations and experiments that the EKF with this reduced model has the same performance as the four-dimensional full state space model at much lower computational cost. The sensorless DTC with the reduced model EKF was found to be equal to DTC with the full model EKF in terms of performance and superior in terms of computational cost. All experiments were carried out on a laboratory prototype of the drive with rated power of 250 W.\",\"PeriodicalId\":149779,\"journal\":{\"name\":\"2014 International Conference on Applied Electronics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Applied Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AE.2014.7011706\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Applied Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AE.2014.7011706","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文的目的是研究利用扩展卡尔曼滤波(EKF)对直接转矩控制(DTC)控制的永磁同步电动机(PMSM)驱动进行无传感器控制。DTC的主要缺点是采样周期短。因此,EKF面临的挑战是最小化其执行时间。这是通过使用所谓的减少状态空间模型的驱动只有两个状态变量,转子速度和转子位置。仿真和实验证明,该简化模型的EKF具有与四维全状态空间模型相同的性能,且计算成本更低。结果表明,采用简化EKF模型的无传感器DTC与采用完整EKF模型的DTC在性能上是相等的,在计算成本上是优越的。所有实验都是在额定功率为250 W的实验室样机上进行的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of full-model and reduced-model EKF based position and speed estimators for sensorless DTC of permanent magnet synchronous machines
The aim of this paper is to study the use of the Extended Kalman filer (EKF) for sensorless control of a permanent magnet synchronous motor (PMSM) drive controlled by direct torque control (DTC). The main drawback of DTC is the necessity of short sampling period. The challenge for the EKF is therefore the minimization of its execution time. This is achieved by using so called reduced state space model of the drive with only two state variables, the rotor speed and the rotor position. It is proved by simulations and experiments that the EKF with this reduced model has the same performance as the four-dimensional full state space model at much lower computational cost. The sensorless DTC with the reduced model EKF was found to be equal to DTC with the full model EKF in terms of performance and superior in terms of computational cost. All experiments were carried out on a laboratory prototype of the drive with rated power of 250 W.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信