Mayarani Mayarani, Eka Putra Syarif Hidayat, N. H. Apriantoro, Robert Kristian, Muhammad Irsal
{"title":"雅加达Pertamina中心医院放射科龙门直线加速器180°角屋顶天光照射分析","authors":"Mayarani Mayarani, Eka Putra Syarif Hidayat, N. H. Apriantoro, Robert Kristian, Muhammad Irsal","doi":"10.36525/SANITAS.2018.4","DOIUrl":null,"url":null,"abstract":"Principally, the measurement of skyshine radiation exposure is important to be conducted if there is public activity in a certain place in which the source of radiation can emit its scattering radiation to all directions including to the rooftop of a Radiotherapy building. the Regulation of the Head of the National Nuclear Power Energy No. 8 Year 2011 Article 32a and No. 4 year 2013 article 23a namely 1 mSv/year. As for the design of this research, it is quantitative descriptive by conducting the measurement of radiation exposure to 44 points of measurement, research instrumentations used herein are 2 surveymeter, water phantom, Linac Primus 2D Plus. Result radiation exposure measurement are 6 point areas with the values above 1 mR/hr. Each of the average value of the measurement of the exposure rate at each point is calculated by the annual dose formula. All the final calculation results with the annual dose formula in mSv/year unit yields the values below 1 mSv/year at the 44 points measurement. the rooftop area of Radiotherapy building through Child Polyclinic Pertamina Central Hospital is under a safe limit with all calculation results of annual dose values below 1 mSv/year.","PeriodicalId":333392,"journal":{"name":"SANITAS : Jurnal Teknologi dan Seni Kesehatan","volume":"79 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Analysis Of Rooftop Skyshine Radiation Exposure With Angle Of Gantry Linear Accelerator 180° In Radiotherapy Unit Of Pertamina Central Hospital Jakarta\",\"authors\":\"Mayarani Mayarani, Eka Putra Syarif Hidayat, N. H. Apriantoro, Robert Kristian, Muhammad Irsal\",\"doi\":\"10.36525/SANITAS.2018.4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Principally, the measurement of skyshine radiation exposure is important to be conducted if there is public activity in a certain place in which the source of radiation can emit its scattering radiation to all directions including to the rooftop of a Radiotherapy building. the Regulation of the Head of the National Nuclear Power Energy No. 8 Year 2011 Article 32a and No. 4 year 2013 article 23a namely 1 mSv/year. As for the design of this research, it is quantitative descriptive by conducting the measurement of radiation exposure to 44 points of measurement, research instrumentations used herein are 2 surveymeter, water phantom, Linac Primus 2D Plus. Result radiation exposure measurement are 6 point areas with the values above 1 mR/hr. Each of the average value of the measurement of the exposure rate at each point is calculated by the annual dose formula. All the final calculation results with the annual dose formula in mSv/year unit yields the values below 1 mSv/year at the 44 points measurement. the rooftop area of Radiotherapy building through Child Polyclinic Pertamina Central Hospital is under a safe limit with all calculation results of annual dose values below 1 mSv/year.\",\"PeriodicalId\":333392,\"journal\":{\"name\":\"SANITAS : Jurnal Teknologi dan Seni Kesehatan\",\"volume\":\"79 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SANITAS : Jurnal Teknologi dan Seni Kesehatan\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.36525/SANITAS.2018.4\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SANITAS : Jurnal Teknologi dan Seni Kesehatan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36525/SANITAS.2018.4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
主要来说,如果在某个地方进行公众活动,而辐射源会向四面八方散射辐射,包括向放射治疗大楼的天台散射辐射,测量日照辐照量是很重要的。国家核电负责人条例2011年第8年第32a条和2013年第4年第23a条,即每年1 mSv。对于本研究的设计,通过对44个测量点的辐射照射量进行测量进行定量描述,使用的研究仪器为2台测量仪、水影仪、Linac Primus 2D Plus。结果辐射暴露测量值在1 mR/hr以上的有6个点区。每个点的照射率测量平均值由年剂量公式计算。44个测点的年剂量公式(以毫西弗/年为单位)的最终计算结果均低于1毫西弗/年。经帕塔米纳中心医院儿童综合诊所的放射治疗大楼屋顶面积均在安全范围内,所有年剂量计算结果均低于1毫西弗/年。
Analysis Of Rooftop Skyshine Radiation Exposure With Angle Of Gantry Linear Accelerator 180° In Radiotherapy Unit Of Pertamina Central Hospital Jakarta
Principally, the measurement of skyshine radiation exposure is important to be conducted if there is public activity in a certain place in which the source of radiation can emit its scattering radiation to all directions including to the rooftop of a Radiotherapy building. the Regulation of the Head of the National Nuclear Power Energy No. 8 Year 2011 Article 32a and No. 4 year 2013 article 23a namely 1 mSv/year. As for the design of this research, it is quantitative descriptive by conducting the measurement of radiation exposure to 44 points of measurement, research instrumentations used herein are 2 surveymeter, water phantom, Linac Primus 2D Plus. Result radiation exposure measurement are 6 point areas with the values above 1 mR/hr. Each of the average value of the measurement of the exposure rate at each point is calculated by the annual dose formula. All the final calculation results with the annual dose formula in mSv/year unit yields the values below 1 mSv/year at the 44 points measurement. the rooftop area of Radiotherapy building through Child Polyclinic Pertamina Central Hospital is under a safe limit with all calculation results of annual dose values below 1 mSv/year.